![Interlogix 4 SERIES Configuration Manual Download Page 21](http://html1.mh-extra.com/html/interlogix/4-series/4-series_configuration-manual_2077133021.webp)
TruVision HD-TVI Series 4 PTZ Dome Camera Configuration Manual
19
ZONE NO.
Select a zone number ranging between 1 and 8.
<UNDEFINED>
This is the zone label.
If the zone has been defined, the zone label is displayed
under the number. If it has not been defined,
UNDEFINED is displayed under the number.
EDIT ZONE
Follow the prompts to set the left and right limits.
ZONE STATUS
This shows the current status of the zone.
SCAN STATUS
ON
: Enable zone scanning.
OFF
: Disable zone scanning.
CLEAR ZONE
Clear the zone settings.
Video Setting
Modify the video output standard, including resolution and frame rate, as desired.
IR Parameter
You can configure the IR parameters including the IR sensitivity, N/M LED
current as well as LED control, etc.
Note:
The IR parameter settings are supported by IR PTZ domes only.
IR PARAMETER
IR SENSITIVITY MEDIUM
N/M LED CURRENT 8
FAR LED CURRENT 8
REFERENCE ZOOM 2
LED CONTROL AUTO
SWITCH DELAY(S) 2
SMART IR 0
BACK EXIT
IR SENSITIVITY
Set the sensitivity of the IR LED to
HIGH
,
MEDIUM
or
LOW
.
N/M LED
CURRENT
Select the current of the near/middle IR LED from between 1 to 10.
FAR LED
CURRENT
Select the current of the far IR LED from between 1 to 10.
REFERENCE
ZOOM
When the actual zoom rate is greater than the zoom limit, the IR
switches to long-distance IR LED.