12
Internal RAID Section (MESAN15)
To replace the internal RAID section:
1. Open the base unit and remove the necessary parts as described in Chapter 1.
2. Remove the CD-ROM drive as described previously in “Internal SCSI Drives.” Support the drive
as you remove it.
3. Remove the RAID disk drives from the slots and place the drives onto a flat antistatic surface.
4. Disconnect the cables (except the sensor cable) attached to the internal RAID subsystem. Refer to
the following figure.
5. Remove the four screws from the top, and the two screws on either side, of the RAID subsystem.
Refer to the following figure.
RAID SCSI
Cable
Drive Installed
Cable
Sensor
Cable
Screws (2
each side)
Power
Cables
Screws (4)
6. Slide the RAID subsystem out of the base unit. Disconnect the sensor cable.
7. Connect the sensor cable to the new RAID subsystem. Slide the subsystem into the base unit.
8. Replace the eight screws removed previously.
9. Reconnect the internal cables.
Summary of Contents for InterServe 600 Series