72
J4, MPWS138, Power Supply 1
Pin
Signal
Pin
Signal
Pin
Signal
1
AC_Line_2
7
No Connect
13
AC_Neutral_2
2
No Connect
8
AC_Ground
14
No Connect
3
-5.1V
9
Fan_OK_2
15
CS_RTN
4
-12V
10
+3.3V_CS
16
DC_OK_1
5
+12V
11
+12V_CS
17
AC_OK_1
6
Ground
12
+5.1V
18
RMT_ON_OFF
J5, MCBL048A, Main Power
Pin
Signal
Wire Color
Pin
Signal
Wire Color
1
+3.3V
Orange
13
+5V
Red
2
+3.3V
Orange
14
Ground
Black
3
+3.3V
Orange
15
Ground
Black
4
Ground
Black
16
+5V
Red
5
Ground
Black
17
Ground
Black
6
Ground
Black
18
-12V
Blue
7
+3.3V
Orange
19
+5V
Red
8
+3.3V
Orange
20
-5V
Red
9
+5V
Red
21
Ground
Black
10
Ground
Black
22
+12V
Yellow
11
+5V
Red
23
Ground
Black
12
Ground
Black
24
Power Good
Green
NOTE
The DC Power Good signal is a TTL-compatible signal that initiate s an orderly start-up procedure under
normal input operating conditions. During power up, this signal should remain low (< 0.8 VDC) for at
least 100 ms after the +5.1 VDC output has reached its minimum sense level of 4.75 VDC. The signal
should then transition to high (> 2.4 VDC) to indicate a stable power source. The signal drives an LED
on the back of the power supply to indicate the status (green is good, off is no signal).
NOTE
The AC Power Good signal is a TTL-compatible signal that transitions to h igh to indicate that the AC
input voltage is within the 90 - 132 VAC or 180 - 264 VAC range. The signal drives an LED on the back
of the power supply to indicate the status (green is good, off is no signal). Provided there is an AC
input, this signal must be available to report whether the outputs are non-functional or functional.
J6, MPWS138, Power Supply 2
Pin
Signal
1,3,5,8,10,12
+5.1V
2,4,6,7,9,11,14,16,18
Ground
13,15,17
+3.3V