26
System Disk Fan (MCBLY690)
For InterServe 615 and 615UW systems without the internal RAID subsystem, a fan in the power
supply access panel provides cooling to the system hard disk drive.
To replace the system disk fan:
1. Open the base unit and remove the necessary parts as described in Chapter 1.
2. Remove the screws from the back cover as shown in the following figure. Pull on the side of the
cover opposite the AC receptacle to disengage it.
Screws
Power Supply
Access Panel
System Disk
Fan
Screws
CAUTION
Do not remove the two screws at the top of the chassis. The power supply will fall down, damaging the
system hard disk drive.
3. Disconnect the fan power cable from the system board J12.
4. Using a No. 1 Phillips screwdriver, remove the fan from the panel.
5. Attach the new fan to the back panel and connect the fan power cable to the system board.
6. Replace the back panel and close the base unit.