maximum of the absolute values, so that both positive maximum and negative maximum
values are determined.
F
IGURE
56
-
M
AX VALUES ARE MAXIMUM OF ABSOLUTE VALUES
4.5.3.
Value transmission
– Which values are in the value frame: All channels are either actual
values, maximum values or minimum values.
F
IGURE
57
-
V
ALUE TRANSMISSION
4.5.4.
Number of Channels in Frame
– Number of input channel values in the measuring data
frame. With smaller numbers, higher data frequencies are possible.
F
IGURE
58
-
M
EASURING VALUES
/
F
RAME SIZE
4.5.5.
Frame / Value Type
– Data type of measuring values in the value-frame that device