I N T E R F AC E M O D E L 9 8 4 0
MO D E L 9 8 4 0 P G 9
P U B .
6 0 3 2 - 0 1
OPTION ~
TEDS TEMPLATE 33 (BRIDGE SENSOR) SUPPORT
The Model 9840 will now support TEDS Template 33 equipped sensors. It is a true plug
and play. No power cycle is required when a TEDS enabled sensor is attached. The
calibration data immediately gets loaded. The following units are supported from the
TEDS Template 33:
Physical
Measurand
Case:
Physical
Unit
Cell
Type
4
N
Load
5
lb
Load
10
Nm
Torque
11
oz-in
Torque
12
Pa
Load
13
psi
Load
14
Kg
Load
15
G
Load
All TEDS Template 33 parameters can be read through the touch screen or Serial. If the
annunciator is turned on, a “T” TEDS annunciator is displayed when the TEDS is turned
on. It appears in the top right of each display. It is on solid when a supported TEDS
Template 33 sensor is attached, otherwise it will blink. It is associated with the channel of
the selected item. If TEDS is turned off and AutoID is turned on, the annunciator will be a
“t”, indicating that Tag IDs can still be read. TEDS and AutoID are enabled/disabled
through the System Options menu on the touch screen or via RS-232 command.
Note:
If TEDS and Auto ID are both enabled, a supported TEDS sensor will override
AutoID and the TEDS parameters will be loaded. Also, if TEDS is off and Auto ID is on, a
TEDS sensor can be used as an Auto ID sensor. This is because they both contain the 8
byte Tag ID.