Reset Tare, Peak, Valley or Position
OPT
Command (R)
This command allows you to reset the tare, peak, valley, or position readings. The format
is R(tare A)(peak A)(valley A)(tare B)(peak B)(valley B)(position select), where the selects
are either a 0 (don’t reset) or a 1 (reset). Thus you can reset any combination of these
readings with a single command.
Example:
@123R111111111111
Acknowledge:
@ 123 Reset - Tare A Peak A Valley A Tare B Peak B Valley B
Tare C Peak C Valley C Tare D Peak D Valley D
Example 2:
@123R100100100000
Acknowledge 2:
@ 123 Reset - Tare A Tare B Tare C
OPTION ~
Display Hold / Freeze Display Command (X)
In Run Mode, the freeze display command
will freeze and unfreeze the run mode
numerical display and the values sent from the unit for RS232 output using either the
remote Value or Print command. Send the command once to freeze the display and
output at the current value. Send again to return display and output to actual reading
from sensor