SC User Guide — V
3.14
www.intelliview.ca
37
Analytics Rules
Section 3: Analytics & Alarm Rules
6. Port Number with KMH
- This option
becomes available when the Bird Detection
or the Speed Camera rule is selected. The
Port number corresponds to the device
connected to the SmrtHVR, such as a n
IntelliView radar gun. Your entry in the
KMH field will indicate the maximum speed
the camera will remain inactive. Above the
specified value, the camera will be triggered
to take a photo.
7. Modbus
- This rule applies to the
SmrtHVR operating as a Master or Client
Device in a Serial or TCP/IP MODBUS
environment.
Before this setting can be
configured, a Modbus device must first be
added. (See Section 9 of SmrtHVR manual
for setup instructions. Note: a technical
person is required to facilitate this setup.)
8. Rule Shape with Color
Match
- This applies to the
Color Match Detection (for
liquid leak detection), the Fire
and the Missed Flame rules
and requires the specification
of a color/s that closely
resembles the color of the
targeted object (e.g. oil). The
Configure button loads the
color settings and the Target
Color button is used for color
selection. Only for the Color
Match Detection rule, up to 10
colors can be added via the
Add button in the Color Match
Configuration window (where
the right arrow is pointing in
Figure 32).
Figure 30 - Port
# with KMH
Figure 31 -
Configuring Modbus
from the Alarm Rule dialog
Figure 32 -
Configuring
the Color Match Rule