background image

 

 

19

 

9

 

Technical specifications 

                            Items 

ThermalTronix

 TT-CXL-DVACS Series 

Thermal Imaging 

Camera

 

 

                Detector characteristics 

Detector type 

Un-cooled FPA micro-bolometer 

Resolution 

384*288 

Detector pitch 

25μm 

Frame rate

 

50HZ

 

                  Image characteristics 

Lens 

TT-C1009XL-DVACS 

f=9mm 

TT-C1018XL-DVACS 

f=18mm 

TT-C1037XL-DVACS 

f=37mm 

TT-C1050XL-DVACS 

f=50mm 

NETD 

≤100mk 

Focus Range 

Athermalized, focus-free 

                          Functions 

Brightness/gain 

control 

Manual brightness/gain; Automatic brightness/manual 

gain; Automatic brightness/gain 

Automatic 

brightness/gain 

configuration 
adjustment     

2 fixed patterns, 8 users from definition establishment 

pattern 
 

Polarity reversal 

Black hot/white hot 

Electronic zoom 

2x 

Noise reduction 

function 

Yes 

Image 
intensification 
function 

Yes 

Calibration 

Automatic calibration 

CCD Camera

 

Resolution

 

Total pixels 795(H)x596(V), Effective pixels 752(H)x582(V)

 

Imaging Device 

1/4″Super HAD CCD 

lens 

3.66-91.36mm(F1.65-3.0), 25x optics, 16x digital   

PTZ 

Horizontal 

Resolution 

Color: 600TV lines, B/W:700TV lines 

Horizontal rotation 

degrees   

0° 

~

 360° continuous rotation 

vertical rotation 

degrees 

-90°

+90° 

Horizontal rotation 
speed 

0.01°

60°/S 

vertical rotation 

speed 

0.01°

30°/S 

Heater 

YES 

Fan 

YES 

Power supply 

Voltage 

AC24V 

Power 
Consumption 

<250W

including heating

 

Environment 

Operating 
temperature 

-20

℃ 

~

 +55

 

Storage 

temperature 

-45

 

~

 +70

 

Protection 

IP66 

Physical 

characteristics 

Weight 

≤17Kg 

Dimensions 

322mm(W)×470mm(H)×268mm(D) 

Interface 

Input voltage 

AC24V 

Analog video 

2 BNC, PAL   

Serial port 

RS485 (PELCO-D/PELCO-P) 

 

 

 

Summary of Contents for ThermalTronix TT-C1009XL-DVACS

Page 1: ...0 ThermalTronix TT CXL DVACS Series Thermal Camera Specifications User Manual...

Page 2: ...nty If the product does not operate properly in normal conditions please let us know Intellisystem Technologies will resolve the problem for free of charge The warranty period is 1 years However the f...

Page 3: ...protect it properly during usage storage and transportation where improper use such as drop and collision will cause damage to the device Make sure that the power control connection is reliable If the...

Page 4: ...ermal camera control key description 7 3 3 CCD camera keys description 7 4 Thermal imaging camera menu 8 4 1 Main menu operation 8 4 2 Setting secondary menu 10 4 3 Com sub menu 12 4 4 Mode sub menu 1...

Page 5: ...ustment Image Noise Reduction function reduce Image background noise Image enhancing function enhance the ability to detect small object CCD camera With the state of the art digital signal processing...

Page 6: ...5 1 2 INCLUDED TT CXL DVACS Series List for accessories and files accessory quantity remark PTZ Camera 1 AC24 Power Adapter 1 User manual 1 Packing list 1 qualification 1...

Page 7: ...and protocol board 4 DIP switch cover Definition refers to chapter 5 5 Wire hole Used to connect power supply monitor and RS485 control 2 2 Connector definition The control wire is from bottom of PT s...

Page 8: ...d address PELCO D baud 9600 address 1 3 2 Thermal camera control key description Before the operation Pls set address 2 firstly 3 3 CCD camera keys description Before the operation pls set address 1 f...

Page 9: ...cursor Press key FOCUS or FOCUS to change the value where the cursor is Auto save when exit 1 Auto XXX Display the current image auto mode Three options 0 manual gain manual brightness 1 manual gain a...

Page 10: ...ey FOCUS or FOCUS show the password dialogue Press FOCUS FOCUS FOCUS FOCUS FOCUS FOCUS to enter setting menu dialogue This password is suitable for all the password dialogue box in the thermal imaging...

Page 11: ...o Pic 3 Input the password to enter refer to Pic 4 Press key LENS move the cursor press key FOCUS or FOCUS to change the value or get into the submenu where the cursor is Auto save when exit 1 COM Set...

Page 12: ...an 2 hours Setup as L Calibrate 1 time during the 1 minute if working time less than 0 minute Calibrate 1 time during 2 minutes if working time between 10 and 30 minutes calibrate 1 time during 5 minu...

Page 13: ...sor Press key FOCUS or FOCUS to change the value where the cursor is Refer to Pic 5 Auto save when exit 1 ID XXX Address of the IR camera 0 254 2 BauRate XXX Baud 1200 2400 4800 9600 14400 19200 38400...

Page 14: ...ate the Mode option Press key LENS move the cursor Press key FOCUS or FOCUS to change the value where the cursor is Refer to Pic 6 Auto save when exit 1 Gain XXX Range 0 255 2 Bright XXX Range 0 255 3...

Page 15: ...rmPIX XXX minimum pixels of alarm Such as alarm Number 2 so the alarm pixel is 2 2 totally 4 pixels 4 Exit Press key LENS to exit Default Level and Threshold Level 1 650 relatively temperature differe...

Page 16: ...witch SW1 is for PTZ communication address ID using eight binary coding system ranges from 1 to 255 specific DIP rules please refer to table below Note when setup address dip please cut off the power...

Page 17: ...to Pic 10 Pic 9 Pic 10 Pressing SETUP switch up or down move up or down on the menu to COMMUNICATION And press SETUP switch to enter COMMUNICATION menu shown as Pic 11 1 Protocol Must be PELCO D other...

Page 18: ...rcuit board Refer to Fig 12 which installed in the CCD camera housing Refer to Pic 1 Refer to Fig 12 Pic 12 Pic 13 J3 interface address switch from left to right is note as 1 2 3 4 bit Up means off do...

Page 19: ...nge the protocol board address again refer to 4 4 The address of PT and protocol must be same Cannot operate the thermal camera Address of thermal camera is not right change the address of thermal cam...

Page 20: ...k hot white hot Electronic zoom 2x Noise reduction function Yes Image intensification function Yes Calibration Automatic calibration CCD Camera Resolution Total pixels 795 H x596 V Effective pixels 75...

Reviews: