background image

Preface

Limited warranty and limited responsibility

Respected users:
How are you! Thank you for purchasing our instrument. In order to use it in 
a better manner, we remind you to read the instruction for use carefully 
before use and keep it properly so as to look up in the future use.

Xintai Instruments and Apparatus Co., Ltd guarantees that the product 
enjoys warranty service of one year from the purchase date.
But the warranty is not applicable to fuse and disposable battery or the 
damage caused by improper operation, accidents, negligence, misuse, 
remodeling, pollution and abnormal condition of the operation environment. 
The distributor has no right to provide any warranty in the name of Xintai 
Instruments and Apparatus Co., Ltd.
Xintai Instruments and Apparatus Co., Ltd authorizes the retail dealers to 
provide new products or unused products to final customers but does not 
authorize them to provide guarantee with wider scope or different contents.
Only the products that are purchased through distributors authorized by 
Xintai Instruments and Apparatus Co., Ltd or products that the purchaser 
paid according to proper international price can enjoy the warranty support 
of our company. When the product bought in a country is sent to another 
country for repair, Xintai Instruments and Apparatus Co., Ltd reserves the 
right to charge the import fees for the parts and components to be repaired 
or replaced from the purchasers.

When warranty service is repaired, please contact the service center 
authorized by Xintai Instruments and Apparatus Co., Ltd to obtain the 
authorization information for return. Then post the product together with 
problem description to the service center with postage and insurance 
expenses prepaid. Our company will not undertake any responsibility for 
any damage occurred during the process of transportation. The product will 
be posted to the purchaser after repair with the transportation expenses
 paid by the purchasers.
If the product failure is verified by negligence, misuse, pollution, change, 
accidents or improper operation or handling after inspection, including the 
over voltage failure caused by use without following the rated value 
stipulated by the product or daily service wear the of the parts, our 
company will estimate the repair expenses and carry out repair after 
obtaining the consent of the purchasers. The product will be posted back to 
the purchaser after repair with the transportation expenses paid by the 
purchasers.
The guarantee is the only compensation that users can be obtained and 
does not include other express or implied guarantees. Xintai Instruments 
and Apparatus Co., Ltd will not undertake any responsibility for any special, 
indirect, accidental or subsequent damage or loss, including any data loss 
caused by any reasons or inference.
Because some countries or states do not allow implied warranties and 
incidental or consequential damages.Restrictions, so the above limitation of 
liability and regulations may not apply to every buyer.
The users shall make promise that they familiarize with the application field 
and occasi on. The purchase indicates that the users are deemed to know  
the suitability for the products.

www.xintest.com.cn

1

www.xintest.com.cn

2

Summary of Contents for HT H8

Page 1: ... Xintai Instruments and Apparatus Co Ltd to obtain the authorization information for return Then post the product together with problem description to the service center with postage and insurance expenses prepaid Our company will not undertake any responsibility for any damage occurred during the process of transportation The product will be posted to the purchaser after repair with the transport...

Page 2: ...ge the product Don t assemble or dismantle the product without permission The product is a type of super precise equipment Don t try to dismantle assemble or remodel any part of the product Repair of the product should be made by technical personnel designated by Xintai Company Avoid damage to probe of the product Note don t put the product close to strong heat source directly such as electric iro...

Page 3: ...ous consequences Do not touch the electric wire with wet hands It is possible to cause electric shock when touching the electric wire with wet hands When pulling out the electric wire hold the electric wire head rightly to pull out the wire Don t pull off the electric wire directly Otherwise the electric wire may be broken causing electric shock and fire Forbid dip the product into water caught in...

Page 4: ...se power it off immediately Otherwise the instrument may be damaged Operation is not allowed unless the water condensation disappears For a long time infrared thermal imaging detection technology has become an important means to ensure Industrial safety in developed countries The application field includes electric power metallurgy petro chemistry machinery coal traffic fire control and national d...

Page 5: ...of the infrared lens Clean the lens The following major functions increase the product s accuracy and usability The radiation coefficient may be adjusted to increase the measurement accuracy of objects with half reflection surface The highest temperature and lowest temperature cursor may guide the users to the areas with highest and lowest temperature of the thermal images The selectable color pal...

Page 6: ...ttery level is low the top right of the screen will display Please charge in time through Micro USB interface www xintest com cn 11 www xintest com cn 12 Infrared image resolution Visible image resolution LCD resolution Field angle Thermal sensitivity Temperature measurement range Measurement accuracy Emissivity Frame rate of thermal images Wavelength coverage Focus mode Color palette 300000pixel ...

Page 7: ...ture Storage temperature Relative humidity Working time Built in chargeable 26650 battery Detachable Selectable 5 minutes 20 minutes not power off automatically 0 to 45 20 to 60 85 RH 3 4 hours JPG Setting command Language Unit language date time information USB Micro USB 2 0 1 www xintest com cn 13 www xintest com cn 14 Storage capacity Built in 8G Actually available 6 6G 256mm 97 2mm 128 9mm 635...

Page 8: ...corner of the screen Battery Micro USB Please open the cap in use 2 www xintest com cn 15 www xintest com cn 16 The highest temperature cursor used to indicate the highest temperature position in the screen area It will move with the movement of the highest temperature The cursor displays red The temperature value is displayed at bottom left corner of the screen Maximum value minimum value of fiel...

Page 9: ...t up press key and the screen bottom will display highest lowest temperature column Press can also hide it LCD screen display After turning on the power the screen shows the thermal imaging status Note Time adjustment may be required when you move the camera between environments with widely varying ambient temperatures Image capture Press the image capture key When the capture is successful the sc...

Page 10: ...in Use USB line to connect the USB port and then computer to read the images or save it into computers images or save it into computers Measuring temperature range conversion Press the button for 2 seconds the temperature measurement range is 20 C 550 C and the icon will be displayed on the interface Press the button for 2 seconds the temperature measurement range is 20 C 120 C and the icon will b...

Page 11: ...alette Press to return Press MENU key to exit from the menu The palette can be used to change the pseudo color display of the infrared image on the display Some tune Swatches are better suited for specific applications and can be set up as needed The palette is divided into rainbow iron red cool white hot black hot five palettes These palettes work best with high thermal contrast and provide addit...

Page 12: ...with low radiation coefficient The emissivity is usually set as 0 3 at the time of measurement Correct setting of the value of emissivity is very important for you to carry out the most correct temperature measurement The surface emissivity will produce giant impact on surface temperature measured by the product Understanding the surface emissivity will enable you to obtain correct temperature mea...

Page 13: ... change the value After themodification is completed press SELECT ENTER to confirm then press to return The MENU button exits the menu www xintest com cn 25 www xintest com cn 26 Thermal radiation 0 90 0 98 0 94 0 96 0 90 0 92 0 96 0 92 0 96 0 96 0 98 0 90 0 95 0 90 0 94 0 94 0 80 0 90 0 89 0 91 0 93 0 96 0 83 0 98 0 98 0 75 0 80 0 96 0 80 0 95 0 97 0 94 0 90 0 70 0 94 0 81 0 78 0 78 0 82 0 90 0 8...

Page 14: ...ngs sub menu select MENU automatic shutdown press navigationThe button in the button enters the auto power off setting Can be set to not automatically shut down or 5 points The clock is turned off or turned off in 20 minutes After selecting brightness press the button in the navigation key to enter the brightness setting Can be set to low or medium or bright 4 3 Language Settings After selecting l...

Page 15: ...turn Press MENU exit from the menu As shown in the figure after selecting cold hotspot press the button in the navigation key to enter the cold hotspot setting As shown in the figure after selecting set time press in the navigation key to enter the setting time Press key to select enable or disable the option Then press SELECT ENTER key to determine selection After the setting is completed press k...

Page 16: ...4h After enabling WIFI use the mobile device to search for WIFI The hotspot name is ThermalCamera xxxxxx xxxxxx is the last six digits of the MAC access the device through the IP address 192 168 230 1 In the mobile device you can set the color palette blending degree emissivity maximum minimum value language conversion and synchro nize to the machine The settings on the machine can also be synchro...

Page 17: ...cally Failure cause The battery is not installed The power of the battery is used up Solution Install the battery Replace with new battery or charge it The power of the battery is used up Replace with new battery or charge it The time set for automatic power off is due Restart or change the time for automatic power off after restarting refer to 4 1 Click Image in the mobile device to enter the ima...

Page 18: ...ant specification which causes damage 3 The damage is caused due to that users use and store it improperly or dismantle and repair it without permission and other reasons 4 Damage caused by natural disasters earthquake flood and lightning stroke and external disasters 5 Exceed the warranty period 1 The product enjoys warranty service within one year from the purchase date if it is used normally an...

Reviews: