2.2.8.3.1 View
VACM View is used to view the
information of SNMPv3 VACM Group.
View Name:
enter the security group
name.
View Subtree:
enter the view subtree
that the view belongs to. The
subtree is the oId to match the
oId in the SNMPv3 message. The
match is good when the subtree is
shorter than the oId in the SNMPv3
message.
View Type:
Select the view type —
“Included” or “Excluded” — when the view subtree matches the Oid in the SNMPv3 message.
2.2.8.3.2 Groups
This screen is used to configure the
information of SNMPv3 VACM Group.
Group Name:
enter the security group
name.
Read View:
enter the Read View
name the group belongs to. The
related SNMP messages are Get,
GetNext and GetBulk.
Write View:
enter the Write View
name the group belongs to. The
related SNMP message is Set.
Notify View: enter the Notify View
name the group belongs to. The related SNMP messages are Trap and Report.
Security Model:
enter the security model the group belongs to. Any is suitable for v1, v2 or v3.
USM is SNMPv3-related.
Security Level:
enter the Security level name the group belongs. only NoAuth, AuthNopriv or
AuthPriv can be chosen.
2.2.8.3.3 Users
This screen is used to configure the
information of SNMPv3 USM User.
User Name:
enter the user name of a
specific security group.
Group Name:
enter the security group
name.
Auth Algorithm:
Select the protocol
that SNMP User and Security
Group belong to: “NoAuth,” “Md5”
or “SHA1.” If “NoAuth” is selected,
there’s no need to enter a password.
Auth Password:
enter the password
that the Auth Algorithm (Protocol) belongs to. The password needs to be at least eight digits
or characters.
Priv Algorithm:
Select the protocol that SNMP User and Security Group belong to: “NoPriv” or
“deS.” If “NoPriv” is selected, there’s no need to enter a password.
Priv Password:
enter the password that the Priv Algorithm (Protocol) belongs to. The password
needs to be at least eight digits or characters.
Security Level:
Select the level the group belongs to: “NoAuth,” “AuthNopriv” or “AuthPriv.”