![Intellijel MIDI 1U Manual Download Page 23](http://html1.mh-extra.com/html/intellijel/midi-1u/midi-1u_manual_2074219023.webp)
MIDI 1U Config Column
The right column is used to configure the various parameters of the MIDI 1U you selected in the left
column’s MIDI Input and MIDI Output menus. At the top of the menu is the name of the selected
device and its current firmware version. Beneath are all the available parameter:
MIDI Channe
l
(1 - 16)
Selects the MIDI channel to which the module responds in
Normal (single channel) mode. If MIDI 1U is in
this sets the MIDI channel for CH A.
Dual Mode Channel
(1-16)
This sets the MIDI channel for CH B. Note that the MIDI 1U
must be in
in order for this to have an effect.
Clock Division
Selects a clock division to apply to the incoming MIDI clock.
The divided clock is sent out the
CLK
[A]
output.
/1
clock out = 24 ppq
/3
clock out = 1/32 notes
/6
clock out = 1/16 notes
/12
clock out = 1/8 notes
/24
clock out = 1/4 notes
/48
clock out = 1/2 notes
/96
clock out = whole notes
Clock Mode
Always
The
CLK
[A]
output
always
transmits a clock, even if the
incoming MIDI clock is stopped. In this case, it continues to
transmit clock using the most recently received clock rate.
Running
The
CLK
[A]
output transmits a clock signal only when a MIDI
clock is being received (i.e., is
‘running’
).
RST Output
Reset
The
RST
[B]
jack transmits a trigger signal whenever a MIDI
RESET message is received. This is the factory default.
Run
The
RST
[B]
jack transmits a run gate that stays high (5V) for
as long as the external MIDI clock is running. Stopping the
external MIDI clock sets the gate low (0V). This is useful for
starting/stopping any eurorack sequences in sync with an
external MIDI sequencer.
Trigger Length
(1 - 100ms) Sets the amount of time that the trigger signal (sent from the
TRIG
[H]
jack) stays ‘high.’ The factory default is 5ms.
NOTE: This setting applies only to Normal Mode, since the
TRIG jack is used for CH B’s GATE output in
).
MIDI 1U System Manual