t110W/t130W – Marine Satellite Television System
92
Parameter Settings
•
Scan Offset: The scan offset is to offset the angle difference between the
black marker on the sub-reflector and the optical sensor.
•
EL Adjust: The elevation adjustment is to offset the angle
difference between the mechanical elevation angle and actual elevation angle.
•
Tracking Level Threshold: The tracking level is to set the satellite
signal tracking level.
•
Detect Level Threshold: The detect level is to set the satellite
signal detection level.
•
WRS Detect Level: The WRS detect level is to set the WRS
detection level.
•
Voltage Threshold: The voltage threshold is to distinguish the
voltage between 13 V and 18V.
•
DiSEqC Threshold: The DiSEqC threshold is to distinguish the
0KHz tone and 22 KHz tone.
•
Use WRS Method: Use WRS method is to determine whether
the system uses “WRS Detect Level” or not. Use WRS method and “WRS
Detect Level” are pair functions.
•
Use Offset Difference: Use offset difference is to determine
whether the system uses “Offset Difference” or not. Use Offset Difference and
“Offset Difference” are pair functions.
•
Use Bow Auto Save: Use bow auto save is to determine
whether the system saves the bow information automatically or not.