17
INSTALLING THE ANTENNA
System Cables
Before installing the system cables, you need to take the following points into
consideration.
•
All cables need to be well clamped and protected from physical damage and
exposure to heat and humidity.
•
A cable with an acute bend is not allowed.
•
Wherever a cable passes through an exposed bulkhead or deck head, a
watertight gland or swan neck tube should be used.
RF Cables (Customer Supplied)
Due to voltage losses across the length of the RF coax on L-Band, Intellian
recommends the following 75 ohm coax cable types for standard system
installations. For cables that run longer than 100 meters, please consult Intellian
Technologies.
Run Length
Coaxial Cable Type
Up to 35 meters
RG-6 or LMR-300-75
Up to 60 meters
RG-11 or LMR-400-75
Up to 100 meters
LMR-600-75
Power Requirements
Intellian t110W/t130W has been designed to work on a vessel’s power supply rated
at 110-220 V AC.
Type
Multi-conductor, Shielded
Number of wires
2 conductors for NMEA
5 conductors for Synchro
Gyro Compass / GPS Interface Cable (Customer Furnished)
Figure 8. Recommended RF Cables
Figure 9. Recommended Gyro/GPS Cables