![Intellian i4 Inland Installation And Operation User Manual Download Page 45](http://html1.mh-extra.com/html/intellian/i4-inland/i4-inland_installation-and-operation-user-manual_2073836045.webp)
45
CODE 101
CODE 102
CODE 103
CODE 104
CODE 105
CODE 106
CODE 107
CODE 108
CODE 109
CODE 110
RESULT
STATUS
Data communication between antenna and antenna control unit is
tested. If failed, check the RF cable.
AZ CW limit is tested.
If failed, check the limit sensors, motor and belt for AZ axis.
AZ CCW limit is tested.
If failed, check the limit sensors, motor and belt for AZ axis.
EL axis is tested.
If failed, check the limit sensors, motor and belt for EL axis.
Sub reflector is tested.
If failed, check the sub reflector.
LNB is tested.
If failed, check the LNB and control board.
Skew System is tested.
if failed, check the control board, skew motor, and skew sensor.
Antenna Input Power is tested.
If failed, check the RF cable.
ACU Power is tested.
If failed, check the ACU power cable and Input DC power.
Receiver Power is tested to Receiver cable and Receiver power.
If failed, check the ACU to Receiver cable and Receiver power.
•
Test is passed.
-
Test is skipped.
?
Test is under process.
Number refers to an error code
(••3••• -•••) 3 means error code 103.
CODE*
Summary of Contents for i4 Inland
Page 63: ......