FLX-64 Installation Guide
38
RS232 and TCP/IP System Query
Routing Queries
Signal Status Queries
Description
Command
Response
Output
yy
routing status (only 1 digit)
Status
y
.
xx
V
yy
<CR><LF>
xx
A
yy
<CR><LF>
Routing status of all outputs.
Status.
xx
V
yy
<CR><LF>
xx
A
yy
<CR><LF>
(Repeating sequence starting with output
1, output 2, etc.)
Get analog audio output routing
%9965.
Out 1 2 3 4<CR><LF>
ExtAudio 6 5 1 1<CR><LF>
Get input 1 and 2 audio source
%9966.
Channel 01 is Analog Audio<CR><LF>
Channel 02 is HDMI Audio<CR><LF>
Description
Command
Response
Get input connection status
%9971.
In 1 2 3 4<CR><LF>
Connect Y N N Y<CR><LF>
In 5 6<CR><LF>
Connect Y Y<CR><LF>
Get input device HDCP status
%9973.
In 1 2 3 4<CR><LF>
HDCP Y N N N<CR><LF>
In 5 6<CR><LF>
HDCP N Y<CR><LF>
Get output connection status
%9972.
Out 1 2 3 4<CR><LF>
Connect Y Y N N<CR><LF>
Get active output resolutions
%9976.
Resolution <CR><LF>
Out 1 1920x1080<CR><LF>
Out 2 1920x1080<CR><LF>
Out 1 0000x0000<CR><LF>
Out 1 0000x0000<CR><LF>
Get output digital audio state
%9977.
Out 1 2 3 4<CR><LF>
Audio Y Y Y Y<CR><LF>
Get HDCP enabled list
%9978.
In 1 2 3 4<CR><LF>
HDCPEN Y Y Y Y<CR><LF>
In 5 6<CR><LF>
HDCPEN Y Y<CR><LF>
Summary of Contents for FLX-64