![Intel True Scale Fabric Switches 12200 Installation Manual Download Page 102](http://html1.mh-extra.com/html/intel/true-scale-fabric-switches-12200/true-scale-fabric-switches-12200_installation-manual_2073478102.webp)
12000 Series Switches
True Scale Fabric Switches 12000 Series Hardware
Installation Guide
July 2015
102
Order Number: G91928004US
2. Carefully pull the module out of the chassis.
E.3.4.2
Replacement Procedures
1. Slide the module straight into the open slot until it engages with the backplane
connector.
2. Push the arms in until they lock in place.
3. Make sure the module is operating and the
Status
LED(s) is green.
E.3.5
Management Module Replacement
FRU part number:
• 12800MM01
E.3.5.1
Removal Procedures
1. Loosen the thumbscrew until it releases from the faceplate.
2. Pull the release arm out until the management module disengages from the
backplane connector.
3. Carefully pull the module out of the chassis.
E.3.5.2
Replacement Procedures
1. Slide the module straight into the open slot until it engages with the backplane
connector.
2. Move the release arm in until it locks in place.
3. Tighten the thumbscrew.
4. Make sure the module is operating and the
Module Status
,
Chassis Status
and
MRL Active
LEDs are green.
Figure 77.
12800 Management Module Removal