Transmitter Description
User Manual
57
STEL-2176
TIMING DIAGRAMS
CLOCK TIMING
tr
tCLKH
tCLK
tf
tCLKL
WCP 52787.c-12/5/97
CLK
Table 51. Clock Timing AC Characteristics
(V
DD
= 3.3 V
±
10%, V
SS
= 0 V, T
a
= Ð40
°
to 85
°
C)
Symbol
Parameter
Min.
Nom.
Max.
Units
Conditions
Clock Frequency (
1
t
CLK
)
165
MHz
t
CLK
Clock Period
6
nsec
t
CLKH
Clock High Period
2.5
nsec
t
CLKL
Clock Low Period
2.5
nsec
t
R
Clock Rising Time
0.5
nsec
t
F
Clock Falling Time
0.5
nsec