Reinstall the retention mechanism assembly and tighten the six captive screws (A).
Reconnect the three flex ribbon cables to the appropriate connectors on the CPU board (B) first
and then reconnect the flex ribbon cables to the appropriate connectors on the I/O board (C).
✏
Important
✏
Flex ribbon cables can be damaged if not properly handled during reconnection. Use the
following recommended procedure to reconnect the flex ribbon cables:
•
Gently insert each flex ribbon cable into its appropriate connector on the CPU board,
taking care to line up the cable connector correctly with the CPU board connector.
•
Carefully bend each flex ribbon cable around the piano hinge on the I/O board.
•
Next, gently insert each flex ribbon cable into its appropriate connector on the I/O
board. Again, be sure to line up the cable connector correctly with the I/O board
connector.
•
Once all the flex ribbon cables have been reconnected, ensure each cable connector
has achieved flush contact with its respective board connector by pressing firmly on
the flex cable backer board.
Reconnect the I/O board power cable (D) to the appropriate connector on the CPU board. Tuck
the power cable into the storage hooks (E) on the underside of the I/O board assembly.
TP00464
A
D
B
E
C
Summary of Contents for SBX44 - Server Compute Blade
Page 12: ...xii Intel Server Compute Blade SBX44 Installation and User s Guide...
Page 24: ...12 Intel Server Compute Blade SBX44 Installation and User s Guide...
Page 30: ...18 Intel Server Compute Blade SBX44 Installation and User s Guide...
Page 62: ...50 Intel Server Compute Blade SBX44 Installation and User s Guide...
Page 84: ...72 Intel Server Compute Blade SBX44 Installation and User s Guide...
Page 92: ...80 Intel Server Compute Blade SBX44 Installation and User s Guide...