7
General Installation Process
12
Install Add-in Card
REMOVE Filler Panel
A
B
Add-in Card
C
Riser Connector
•
Full-height PCIe Card Shown
A
B
C
CAUTION:
Observe normal ESD precautions
when installing add-in cards.
Insert add-in card until it sits in the riser connector.
Secure add-in card with screw as shown.
Note:
Make sure that all empty add-in card slots have
filler panels installed.
Note: Add-in card install sequence for low-profile add-in
cards is the same.
Remove the filler panel from the add-in card slot and
remove the screw as shown.
A
B
IMPORTANT NOTE: If you do not
install a device at this location,
install the optical device bay filler
panel shown below.
This is required to maintain
proper system cooling.
Rear View
of Optical
Drive
A
Install the plastic guide onto the back
of the drive and attach with two screws
as shown.
Insert the optical drive into chassis opening
and push all the way until it stops.
C
Connect the cables as shown.
Optical
Device
Assembly
B
Data
Power
Optical
Drive
C
9
Install Optical Drive
Riser Card
Connector
Grasp the riser assembly with
both hands and pull up to
remove from system.
CAUTION:
Place the riser
assembly
upside down to
avoid damage
to the riser card
connector.
11
Remove Add-in Card
Riser Assembly
Align the two holes on the air duct with the alignment
pins on the chassis and install the air duct into place.
Use care to avoid pinching system cables.
10
Install the Air Duct
Summary of Contents for R1000SP
Page 2: ...This page is intentionally left blank...
Page 20: ...G64256 003...