10. 12V TriggerA
Set when outputting the control signal (maximum 12 V/
100 mA) through the 12V TRIGGER OUT A jack.
Different settings can be set for each input source. You
can enable power link operation when you connect the
unit and the external devices equipped with 12V trigger
input jack.
Delay:
Set after how many seconds the 12V trigger
output will occur in response to the unit’s operation. As
some devices cause a large current when they turn on,
delay the output if such devices are connected.
0sec
to
3sec
(default setting: 0sec)
BD/DVD
,
CBL/SAT
,
PC
,
GAME
,
TV/TAPE
,
CD
,
PHONO
,
TUNER
,
NET
,
BLUETOOTH:
Set the 12V trigger output
setting.
Main
(default setting): 12V trigger is output when this
input source is selected as the input for the main room.
Zone2
: 12V trigger is output when this input source is
selected as the input for zone 2.
Main/Zone2
: 12V trigger is output when this input
source is selected as the input for the main room or
zone 2.
Off
: 12V trigger is not output.
∫
11. 12V TriggerB
Set when outputting the control signal (maximum 12 V/25
mA) through the 12V TRIGGER OUT B jack. Different
settings can be set for each input source. You can enable
power link operation when you connect the unit and the
external devices equipped with 12V trigger input jack.
Delay:
Set after how many seconds the 12V trigger
output will occur in response to the unit’s operation. As
some devices cause a large current when they turn on,
delay the output if such devices are connected.
0sec
to
3sec
(default setting: 1sec)
BD/DVD
,
CBL/SAT
,
PC
,
GAME
,
TV/TAPE
,
CD
,
PHONO
,
TUNER
,
NET
,
BLUETOOTH:
Set the 12V trigger output
setting.
Main
: 12V trigger is output when this input source is
selected as the input for the main room.
Zone2
(default setting): 12V trigger is output when this
input source is selected as the input for zone 2.
Main/Zone2
: 12V trigger is output when this input
source is selected as the input for the main room or
zone 2.
Off
: 12V trigger is not output.
∫
12. 12V TriggerC
Set when outputting the control signal (maximum 12 V/25
mA) through the 12V TRIGGER OUT C jack. Different
settings can be set for each input source. You can enable
power link operation when you connect the unit and the
external devices equipped with 12V trigger input jack.
Delay:
Set after how many seconds the 12V trigger
output will occur in response to the unit’s operation. As
some devices cause a large current when they turn on,
delay the output if such devices are connected.
0sec
to
3sec
(default setting: 2sec)
BD/DVD
,
CBL/SAT
,
PC
,
GAME
,
TV/TAPE
,
CD
,
PHONO
,
TUNER
,
NET
,
BLUETOOTH:
Set the 12V trigger output
setting.
Main
: 12V trigger is output when this input source is
selected as the input for the main room.
Zone2
: 12V trigger is output when this input source is
selected as the input for zone 2.
Main/Zone2
(default setting): 12V trigger is output
when this input source is selected as the input for the
main room or zone 2.
Off
: 12V trigger is not output.
DTM40.7_mst.book 39 ページ 2015年7月24日 金曜日 午後12時58分