Functions
MoRoS ADSL 2.1 PRO
13.4.2
Configuring the Function of the Inputs
The MoRoS ADSL 2.1 PRO can establish a pre-configured dial-out connection, an
OpenVPN tunnel, a PPTP tunnel, an IPsec tunnel or a serial Ethernet gateway
connection, as soon as input 2 is closed for at least 4 seconds, i.e. connected to
"GND". When activating the input, a dial-out or tunnel or connection set-up is
performed as configured in the according menu. The connection will remain as
long as the connection configuration allows.
Configuration via the web interface
In order to configure the function of input 2, select in the menu "In-
/Outputs" on the page "Inputs" either the option "none", "Dial-Out
automatically", "Establish OpenVPN tunnel", "Establish IPsec tunnel", or
"Establish outgoing serial Ethernet connection".
The respective Dial-Out or OpenVPN/IPsec functions must be configured,
to be triggered by the input.
In order to trigger a PPPoE dial-out connection only with input 2, check
the checkbox "Exclusively (dial-on-demand is deactivated)". This function
is not effective, if the LAN ext interface is configured for a PPPoA
connection.
In order to terminate a Dial-Out connection by opening input 2, check the
checkbox "Cancel if no longer connected with GND".
In order to trigger an OpenVPN tunnel only with input 2, check the
checkbox "Establish exclusively via input (not automatically after Dial-
Out)".
In order to terminate an OpenVPN tunnel by opening input 2, check the
checkbox "Cancel if no longer connected with GND".
In order to trigger a PPTP tunnel only with input 2, check the checkbox
"Establish exclusively via input (not automatically after Dial-Out)".
In order to terminate a PPTP tunnel by opening input 2, check the
checkbox "Cancel if no longer connected with GND".
In order to trigger an IPsec tunnel only with input 2, check the checkbox
"Establish exclusively via input (not automatically after Dial-Out)".
In order to terminate an IPsec tunnel by opening input 2, check the
checkbox "Cancel if no longer connected with GND".
In order to terminate an outgoing serial Ethernet connection by opening
input 2, check the checkbox "Cancel if no longer connected with GND".
Save your settings by clicking "OK".