Functions and their Configuration
INSYS GSM 4.2
INSYS GSM 4.2 compact
78
Sep-06
6.6
History
The current values from the internal history list are read out and displayed. The INSYS
GSM records the following events continuously in a ring buffer.
The ring buffer always contains the last 200 entries. The buffer will be deleted when re-
setting to factory settings. The entries will be displayed in chronological order on max.
4 pages.
Export as text
The displayed data can be stored as text file. Have this data ready for technical support.
Meaning of the entries:
Reason
Detail
Meaning
RTC ERROR
Internal real time clock is faulty (time stamp empty)
RTC RESET
The internal real time clock has been reset as the gold cap was dis-
charged (power reserve used up). Time stamp: 00:00:00 01.01.03
GSM ERROR
Instruction from controller to GSM engine could not be processed cor-
rectly (e.g. AT command, dial-up, SMS dispatch…)
SIGNAL ERROR
Field strength not ascertainable (
AT**SIGNAL?
: 99)
LOGOUT
GSM engine logged out (update interval like STATUS LED)
LOGIN
GSM engine logged in (update interval like STATUS LED)
REMOTE PARAM
Remote configuration started (*** detected)
ALIVE
Alive SMS process starts
RESET
Software/hardware reset
SYSTEM
POWER UP
Power up; upon return of voltage
SECURITY DPW ERROR
Wrong data password or timeout expired