INSYS GSM 4.2
INSYS GSM 4.2 compact
Functions and their Configuration
Sep-06
49
¾
Connection set-up for alarm messages via a data connection
¾
Connection set-up for security callback
Possible values are 1 to 12, default value is 3.
The dispatch will only be attempted once for an acknowledgement SMS after a configu-
ration via SMS.
Procedure: Set number of dialing attempts
To set the number of dialing attempts in the software HSComm, enter the requested
number in the tab "Basic settings"
in the group "GSM connections" in the entry field "Di-
aling attempts".
Pertinent AT commands
AT**DIAL
Dial-up attempts for periodic alive or alarm messages
6.1.4
Auto answer
After the specified number of ring tones, the INSYS GSM will accept a data call.
0
Switched
off
2 to 255
On
Note
Incoming voice calls are automatically accepted when DTMF proc-
essing is enabled.
Procedure: Activate auto answer
To activate auto answer in the software HSComm, activate the check box "Auto answer"
in the tab "Basic settings"
in the group "GSM connection".
Pertinent AT commands
ATS0
Auto answer