Getting Started 

Fully charge your RemoteLinc 2 prior to programming or anytime the unit is not responding. RemoteLinc 
2 charges via a USB cable (Type A to Micro-B, sold separately). The red charging LED will turn off once 
the battery has been fully charged (approximately 1 hour). To turn on RemoteLinc 2, simply slide the 
power switch to the on position.  

Note: RemoteLinc 2 uses a subtle beeper sound to assist setup. It is recommended that you program the 
unit in a quiet area. 

Setting up INSTEON Scenes 

Scene: One or more INSTEON devices which respond to an INSTEON controller. When the scene is 
activated (turned “on”), all devices return to the states they were at when the scene was programmed. 
INSTEON scenes let you activate dramatic lighting moods at the touch of a button. For example, you can 
set all the lights in a scene to dim to 50% or turn certain lights on while turning others off, all with the tap 
of a button on any INSTEON Controller. INSTEON scenes are easy to set up, just follow the directions 
below. 

Maximum number of scenes in RemoteLinc 2 Keypad: 8 (Default is 4) 
Scene Control Functions supported; On, Off, Press & hold Bright, Press & hold Dim, Double-tap Fast On 
and Double-tap Fast Off. 
 

Add RemoteLinc 2 Button to a Scene as a Controller  

Follow the steps below to control a scene (one or more INSTEON devices).  

1)  Tap the RemoteLinc 2 scene button of choice (on or off buttons will both work)  

2)  Adjust the scene responder to the “state” you want when the scene is activated from RemoteLinc 2 

(e.g., 50%, 25% or even OFF)

1

 

3)  Press & hold RemoteLinc 2’s Set button until RemoteLinc 2 beeps 

 

 

 

RemoteLinc 2’s LED will blink 

GREEN

 

4)  Press & hold the responder’s Set button until it beeps (or until its LED/load flashes) 

   

RemoteLinc 

will 

(Beep)-(Beep) 

and its LED will stop blinking 

   

Responder’s 

LED 

will 

stop blinking (it may also 

(Beep)-(Beep)

)

 

5)  Confirm that scene addition was successful by tapping on/off on your chosen RemoteLinc 2 button 

 

 

 

The Responder will toggle between the scene on level and off

 

6)  If you wish to add more responders to RemoteLinc 2, repeat steps 1-5 for each additional scene 

responder (or see 

Add Multiple Responders to a scene

)  

1

 If the Responder is a multi-scene device such as a KeypadLinc, tap the scene button you wish to control until its LED is in the desired state (on or off)

 

Remove RemoteLinc 2 Button from a Scene as a Controller 

If you are no longer going to use an INSTEON responder that is a scene responder of RemoteLinc 2, it is 
very important that you remove its scene membership. Otherwise, RemoteLinc 2 will retry every scene 
command repetitively, thus creating delays and shortening battery life. 

                                                      
 

Summary of Contents for RemoteLinc 2

Page 1: ...RemoteLinc 2 INSTEON Remote Control Keypad 4 Scene 2444A2xx4 Owners Manual Page 1 of 15 2444A2xx4 Rev 10 24 2011 10 50 AM...

Page 2: ...uck Button 8 Advanced Features 8 Add Multiple Responders to a Scene Multi Link 8 Remove Multiple Responders from a Scene Multi Unlink 8 Change Button Scene Configuration e g Change to 8 Button Mode 9...

Page 3: ...nted on wall with no trim plate wireless keypad Mounted on wall in a single gang Decorator trim plate wireless keypad built in look Mounted on wall in a multi gang Decorator trim plate add to the numb...

Page 4: ...e Stuck Button Mode saves battery life by going to sleep if button stuck down Beeper for setup ease Recharges with standard USB charger with via Micro USB Plug 5VDC 9 12 month battery life based on av...

Page 5: ...nt your RemoteLinc 2 anywhere Gang two or more together for more control Can be installed adjacent to existing wired in switches RemoteLinc 2 can easily be removed for portability or recharging Use wi...

Page 6: ...ast Off Add RemoteLinc 2 Button to a Scene as a Controller Follow the steps below to control a scene one or more INSTEON devices 1 Tap the RemoteLinc 2 scene button of choice on or off buttons will bo...

Page 7: ...on Tap Press hold Double tap On Right Turn scene on Brighten scene members until released Turn scene members full bright instantly Off Left v Turn scene off Dim scene members until released Turn scene...

Page 8: ...s the RemoteLinc will automatically stop transmitting to preserve battery life The RemoteLinc 2 will automatically turn back on when the button that was depressed is no longer being pressed Advanced F...

Page 9: ...2nd time for 3 seconds until you hear a beep RemoteLinc 2 s LED will blink RED 3 Press Hold Set Button a 3rd time for 3 seconds until you hear a beep RemoteLinc 2 s LED will blink GREEN 4 Press Hold...

Page 10: ...its LED turns off returns to Ready Mode Turn Beeper On During Usage or Back Off 1 Press Hold Set Button for 3 seconds until you hear a beep RemoteLinc 2 s LED will blink GREEN 2 Press Hold Set Button...

Page 11: ...formation LED State Meaning Add Responder Setup Mode or Blinking Green slowly LED on off Setup Mode Blinking Red slowly Remove Responder Setup Mode Multi Add Responder Setup Mode or Double Blinking Gr...

Page 12: ...nding Warranty 1 Year Limited INSTEON Scenes 4 default configurable to 8 Scene Configurations 4 On Off default 8 Toggle or 8 Always On Maximum scene Links 400 On Off Begin Brightening Begin Dimming En...

Page 13: ...ing Problem Possible Cause Solution RemoteLinc 2 may be out of range of nearest dual band INSTEON device hopper Try moving an access point or other dual band plug in module closer to RemoteLinc 2 The...

Page 14: ...fonctionnement The digital circuitry of this device has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to...

Page 15: ...rms of the above warranty and disclaimer Home automation devices have the risk of failure to operate incorrect operation or electrical or mechanical tampering For optimal use manually verify the devic...

Reviews: