background image

Page 13 of 16                                                                            

 

2342-242/2444A3, 2342-442, 2342-542 Rev: 1/21/2014 7:24 AM

 

Red Blink for ~3 Seconds 

Scene Acknowledge Missing 

LED 

Always used for setup, default On during use 

Setup Button 

Yes 

On/Off Switch 

Yes 

Beeper 

Yes, configurable 

Battery Charging LED 

Yes, Embedded (shines red through case during charge) 

RF Range 

50’ Line-of-Sight 

RF Frequency 

915MHz (US) 

869MHz (EU) 

921MHz (AUS/NZ) 

Retains all settings without power 

Yes, all saved in Non-volatile EEPROM 

Mechanical 

Color  

White 

Plastic 

UV Stabilized ABS 

Button Configurations 

1 Scene (standard), 2 Scene (optional button kit) 

Dimensions 

2.6" H x 1.3" W x 0.39" D 

Weight (w/battery) 

1 Oz. 

Button Style 

Plastic Paddles over Contact Switches 

Optional Hardware 

Wall Mount 

Tabletop Stand 

Visor Clip 

Operating Environment 

Indoors, 32°F to 104°F, up to 85% relative humidity 

Electrical 

Battery type 

3.7 VDC Lithium Polymer, Rechargeable, non-replaceable 

Battery life (between charges) 

> 3 months under standard usage 

Battery Re-charging cycles 

> 500 recharging cycles 

Recharging jack 

Standard, Micro-USB, 5VDC 

Recharging time 

~1 hour 

Sends Low Battery Warning 

Yes 

Troubleshooting 

Problem 

Possible Cause 

Solution 

Mini Remote won’t add a 
scene responder  

Mini Remote may be out of range of 
nearest dual-band INSTEON device 
(hopper)  

Try moving an access point or other dual-band 
plug-in module closer to Mini Remote 

The INSTEON signal may not be 
getting to the “vicinity” of responder 

Make sure phases are bridged, add additional 
INSTEON devices and/or move around existing 
INSTEON devices 

Summary of Contents for Mini Remote 2342-442

Page 1: ...Page 1 of 16 2342 242 2444A3 2342 442 2342 542 Rev 1 21 2014 7 24 AM Mini Remote INSTEON Remote Control Switch formerly RemoteLinc 2 Owners Manual 2342 242 2444A3 US 2342 442 EU 2342 542 AUS NZ...

Page 2: ...7 LED Behavior 8 Turn Unit On Off Pocket Mode 8 Stuck button 8 Advanced Features 8 Add Multiple Responders to a Scene Multi Link 8 Remove Multiple Responders from a Scene Multi Unlink 9 Change Paddle...

Page 3: ...n wall with no trim plate wireless keypad Mounted on wall in a single gang Decorator trim plate wireless keypad built in look Mounted on wall in a multi gang Decorator trim plate add to the number of...

Page 4: ...e Stuck Button Mode saves battery life by going to sleep if button stuck down Beeper for setup ease Recharges with standard USB charger with via Micro USB Plug 5VDC Battery life exceeds 3 months Batte...

Page 5: ...ee table USB Power Adapter 2444B6 For use with Mini Remote USB Charging Cable and any other device that charges via USB cable Wall Mount Bracket 2444B4 Wall mount your Mini Remote anywhere Gang two or...

Page 6: ...emote Button to a Scene as a Controller Follow the steps below to control a scene one or more INSTEON devices 1 Tap the Mini Remote switch top or bottom paddle if in 2 scene mode tap the top of the pa...

Page 7: ...ode Default The switch controls scene members as follows Paddle Tap Press hold Double tap Top Turn scene on Brighten scene members until released Turn scene members full bright instantly Bottom Turn s...

Page 8: ...periods of time Stuck button If a button on Mini Remote is held for more than 4 minutes the RemoteLinc will automatically stop transmitting to preserve battery life The Mini Remote will automatically...

Page 9: ...i Remote will double beep and its LED will turn off Change Paddle Scene Configuration e g Change to 2 Scene Mode 1 Press Hold Set Button for 3 seconds until you hear a beep Mini Remote s LED will blin...

Page 10: ...e for the desired button scene configuration Desired LED Mode Button to Press LED Off Bottom LED On default Top Mini Remote will double beep and its LED will turn off Turn Beeper On During Usage or Ba...

Page 11: ...Setup Mini Remote has a two color LED Green Red which displays helpful information LED State Meaning Blinking Green slowly Add Responder Setup Mode or LED on off Setup Mode Blinking Red slowly Remove...

Page 12: ...442 EU 2342 542 AUS NZ UPC 813922011616 813922012606 813922012972 FCC ID SBP2444A Patent Number 7 345 998 US International Patents Pending Warranty 2 Years Limited INSTEON Scenes 1 default configurabl...

Page 13: ...over Contact Switches Optional Hardware Wall Mount Tabletop Stand Visor Clip Operating Environment Indoors 32 F to 104 F up to 85 relative humidity Electrical Battery type 3 7 VDC Lithium Polymer Rec...

Page 14: ...nds to a responder s that is no longer in use Remove all unused Responders from the Mini Remote HINT If you are using home automation software you can easily check scene membership and eliminate unnec...

Page 15: ...equirements and other relevant provisions of the following Directives 1 Electromagnetic Compatibility Directive 2004 108 EC 2 Hazardous Substance Directive 2005 95 EC Technical data and copies of the...

Page 16: ...ovided for above shall be the full extent of Seller s liability with respect to this product For repair or replacement during the warranty period call the INSTEON Gold Support Line at 866 243 8022 wit...

Reviews: