8
Installation instructions & user guide
T210042 InstaTap office manual v1.01 June 2022
A 3.5 bar pressure limiting valve must be fitted for mains water
pressures above 5 bar, in accordance with local plumbing
regulations. (A pressure limiting valve is supplied as part of the
install rail in the installation kit)
!
Specification
Unit
Under counter
chiller
Under counter
boiler
Capacity
L
N/A
5
Dimensions (W x D x H)
mm
180 x 340 x 390
230 x 415 x 510
Supply voltage
V
230 50Hz AC
230 50Hz AC
Power rating
kW
0.185
2.25
Mains water supply pressure
bar
2 - 5
2 - 5
Fill type
Automatic
Automatic
Recovery per minute
L
0.33
0.38
Water temperature
0
C
5 - 9
80 - 95
(default 95)
Weight (empty)
kg
17
9.9
Weight (full)
kg
19
17.3
Heat up time from cold
mins
-
20
Mains water connection
3/4” BSP
(Install rail 15mm)
3/4” BSP
(Install rail 15mm)
Fuse rating
A
5
13
4.1 Technical data table
SECTION 4 Technical data