59
inconsistent.
Solutions:
1.
Check the OS version. The supported memory capacity varies with the version
of Windows OS. Enter BIOS Setup to view the memory capacity. If the memory is
identified completely, the OS may be unable to access all the installed
memories. For example, Windows server 2008 x86 supports up to 4 G memory;
2.
If the memory is not identified completely in BIOS Setup, confirm that the
corresponding slots have been populated with memories of correct type;
3.
If the instructions above do not resolve the problem, please call Inspur
Customer Service Hotline (1-844-860-0011/1-760-769-1847) or email to
.
7.2.4
Abnormal Network
Symptoms:
The network is disconnected, or the rate is lower than the actual rate of the network
port under the server OS.
Solutions:
1.
Check whether the network cable is connected properly and whether the
network port LED flashes normally to ensure that the network is configured
correctly;
2.
Unplug and plug the network cable back to see if the problem can be solved. If
not, connect the server with a laptop via a known working network cable: If the
network is normal, check the network cable or the switch port; if the network is
faulty, go to Inspur Website https://en.inspur.com
to
download the latest NIC driver;
3.
Check whether the NIC can be identified under BMC Web, BIOS or Shell and
whether the MAC address is correct;
If the instructions above do not resolve the problem, please call Inspur Customer
Service Hotline (1-844-860-0011/1-760-769-1847) or email to
, and inform us of the detailed warning information and
failure.