43
BIOS Setup
Table 8-
5
Create RAID Menu Instruction Table
Interface Parameters
Function Description
Name
Please enter a volume label name less than 16 characters without containing any
special characters.
RAID Level
Please select RAID volume level. If no volume has been created at present, there are
four volume levels of RAID0 (Stripe), RAID1 (Mirror), RAID10 (RAID0+1) and RAID5
(Parity) for selection. Please select volume level according to actual requirements.
RAID0: This RAID volume is allowed to be made on 2 or above disks.
RAID1: This RAID volume is allowed to be made on 2 disks.
RAID10: This RAID volume is allowed to be made on 4 disks, which is only available
when disk quantity is 4 or above.
RAID5 (Parity): This RAID volume is allowed to be made on 3 or above disks.
Select Disks
Select disks to make RAID volume, press Enter, select X, and then press Enter to
return to Create RAID Volume interface.
Strip Size
Please select the strip size, only RAID0 and RAID5 volumes could enable this option.
Capacity
Set the volume capacity.
After completing the above settings, please select [Create Volume], and press Enter. The
system will prompt “WARNING: ALL DATA ON THE SELECTED DISKS WILL BE LOST. Are you sure
you want to create this volume? (Y/N)”. To create an RAID volume, please enter “Y”. A volume
will be created, and all data on the selected disks will be lost. Otherwise, please enter “N”,
to exit volume creation. Here we enter “Y” to create an RAID volume. After the creation is
completed, return to MAIN MENU interface, the created RAID volume will be displayed.
3.3
Delete RAID Volume menu. After entering Delete RAID Volume menu, press [DEL] to
delete the selected RAID volume, and the system will prompt “ALL DATA IN THE VOLUME
WILL BE LOST! Are you sure you want to delete “Volume0*”? (Y/N)”. To delete this RAID
volume, please enter “Y”, to cancel the deletion, please enter “N”.
Figure 8-17
3.4
Reset Disks to Non-RAID menu. After entering Reset Disks to Non-RAID menu, system
Summary of Contents for NF5266M5
Page 1: ...Inspur Server User Manual NF5266M5 ...
Page 109: ...BMC Settings 103 Figure 9 5 Figure 9 6 Figure 9 7 ...
Page 113: ...BMC Settings 107 Figure 9 15 Figure 9 16 Figure 9 17 Figure 9 18 ...
Page 115: ...BMC Settings 109 Figure 9 20 Figure 9 21 Figure 9 22 ...
Page 116: ...110 Figure 9 23 Figure 9 24 ...
Page 118: ...112 Figure 9 27 Figure 9 28 ...
Page 120: ...114 Figure 9 32 Figure 9 33 Figure 9 34 Figure 9 35 ...
Page 122: ...116 Figure 9 37 Figure 9 38 ...