108
9.7 BMC Settings
Select “BMC Settings” on the navigation tree to open the BMC Settings interface. It contains
the interfaces of BMC network, services, NTP, SMTP, alerts, threshold, access control, BMC
share NIC switch and BIOS boot options, as shown in the following figures.
●
BMC network management: Contains BMC network (static IP and DHCP), DNS settings
and network interface bonding and network link information.
●
Services: To configure the BMC’s Web service, KVM service, ssh service, telnet service, etc.
●
NTP settings: To set the BMC time, which has two methods:
Synchronize from NTP server.
Set time manually.
●
SMTP settings: To set the SMTP server information related to alert.
●
Alert settings: To set the alert event filtering and alert targets of BMC management module.
●
Access control: To set IP address fields accessible to BMC.
●
BMC share NIC switch: Contains NCSI type switch, NCSI mode switch and channel switch.
●
BIOS boot options: To set the boot option after BIOS reset.
Figure 9-19
Summary of Contents for NF5266M5
Page 1: ...Inspur Server User Manual NF5266M5 ...
Page 109: ...BMC Settings 103 Figure 9 5 Figure 9 6 Figure 9 7 ...
Page 113: ...BMC Settings 107 Figure 9 15 Figure 9 16 Figure 9 17 Figure 9 18 ...
Page 115: ...BMC Settings 109 Figure 9 20 Figure 9 21 Figure 9 22 ...
Page 116: ...110 Figure 9 23 Figure 9 24 ...
Page 118: ...112 Figure 9 27 Figure 9 28 ...
Page 120: ...114 Figure 9 32 Figure 9 33 Figure 9 34 Figure 9 35 ...
Page 122: ...116 Figure 9 37 Figure 9 38 ...