15
SERVICE CLEARANCE:
A minimum of 300mm (12”)
is required on both the Front
and Top Panels for any service
requirements.
COMBUSTIBLE SURFACES:
Each heater face requires a
150mm (6”) clearance from
combustible surfaces.
Although it is not advisable,
the heater base can be placed
on a combustible surface for
operation.
However, do not install the
heater on carpet.
CLEARANCES
The heater must be installed in a location that allows
clearances for maintenance and inspection. Minimum
distances from combustible surfaces must also be
maintained. All criteria given in the following sections reflect
minimum clearances as stated in the national standards.
However, each installation must also be evaluated, taking
into account prevailing local conditions such as wind speed
and direction, proximity and height of obstructions that may
block ventilation, and proximity to public access areas.