If the heater is installed below the water level of the Pool, the Pressure
Switch must be adjusted by your professional installer.
A flow switch is required if the heater is installed more than 6’ (1.8m)
above the pool water level, or 6’ (1.8m) below the pool water level.
These levels are outside of the operating capability of the supplied
pressure switch.
If the pressure switch cannot be adjusted a flow switch must be
installed and wired to the pressure switch safety circuit in the heater.
TO CHECK THE OPERATION OF THE SWITCH:
1.
Pressure switch should only be checked and adjusted with clean
skimmer, pump basket and filter. Ensure Pump Basket, Skimmer and
Filters have been cleaned prior to adjusting Pressure Switch.
2.
Connect the heater to mains power supply and turn power on.
The thermostat SHOULD Not have a light above the Flow indication.
3.
Turn on pump. A light should now appear above the flow indication.
4.
Turn pump off. The light above the flow indicator should now be off.
5.
If display does not respond in this way, adjust the pressure switch as
detailed below. If display responds correctly, perform a final check with
the heater operating.