Switching

 

on

 

the

 

instrument

The roughness tester is switched on by pressing the key     . The 
ISR-S400,  after  a  number  of  internal  checks  have  been 
conducted  quickly,  indicates  on  the  display                    for  a  few 
seconds  before  moving  on  to  displaying  the  parameters.  This 
indicates to the operator that the instrument is ready to be used. 
Switching-off,  on  the  other  hand,  occurs  automatically  40 
seconds  after  the  last  operation  effected.  If  a  key  is  pressed 
within the 40 seconds, the on time count is reset to zero and, from 
that precise time, extended for another 40 seconds.

All

 

the

 

functions

 

activated

 

directly

 

from

 

the

 

keyboard

 

and

 

those

 

executed

 

from  the

 

menus

 

are

 

only

 

accessible

 

after

 

the

 

instrument

 

has

 

been

 

switched

 

on. 

The  switching  on  is  also  gotten  with  the  special  external  push-
button  (optional)  connected  to  the  data  output,  or  automatically, 
or  when  press  the  keys  on  the  printer,  or  when  the  software 
Measurement Studio communicate with the roughness tester.

Note: when the ISR-S400 switches off at the precise moment 
you  try  to  press  a  key,  you  are  advised  to  wait  for  ½  second 
before switching the instrument on again.

:

1

the

 

ISR

-

S400

 

menus. Use

notes

 

and

 

structure:

The  operator  programs  and  controls  the  instrument’s  functions 
through selection menus and submenus. 
To  activate  the  main  menu  press  the  key        (ENTER)  when  the 
display shows:
1. The results of a measurement.
2. The cut-off.
3. The cut-off number. 
4. An error message.
To exit from the main menu and the submenus press the     and     ; 
the  first  one  immediately  starts  the  measure,  the  second  in  the 
submenus  makes  to  climb  a  level,  in  the  main  menu  it  makes  to 
visualize the parameters.
The structure of the menu can be seen in the figure that follows:

The  selections  made  on  the  submenus  become  operative 
immediately and the active item or the last one we was positioned 
on  is  indicated  by  a  black  background  applied  to  the  item.  To
shift  the  the  selection  and,  as  a  result,  alter  your  selection,  use 
the key     . Access may be had to the submenus by pressing the 
key        .  When  the  menu  or  submenu  contains  numerous  items
that  cannot  all  be  displayed  simultaneously,  you  will  see  on 
display  only  the  items  that  can  be  written  in  full;  the  others  will 
appear  gradually  as  you  move  with  the  cursor.  For  example,  the
main  menu  comprises  8  items  but  only  four  are  displayed  at  a 
time.

2

The pick-up:

The ISR-S400 incorporates the traverse unit mechanism and the 
pick-up  is  fastened  to  the  latter  by  means  of  the  pick-up  support 
articulation.  The  measurements  may  be  made  either  by
holding  the  ISR-S400  in  your  hand  or  fastened  to  a  support  or 
simply  set  down  (with  additional  supports  for  measurements  on 
cylinders and pick-up cover for use when measuring edges).
The  pick-up  support  block  permits  rotation  of  the  pick-up  so  that 
measurements  may  be  made  inside  throats  (pick-up  at  90°),  as 
shown in the figure below.

Menus and Settings 

Summary of Contents for ISR-S300

Page 1: ...MN ISR 300 S E www insize com ROUGHNESS TESTER OPERATION MANUAL ISR S300 V0 ...

Page 2: ... a microprocessor it uses an alphanumeric liquid crystal display LCD and the accumulator adopted permits considerable operating autonomy All the messages and menus can be displayed in one of the following five selectable languages Italian English French German Spanish and Portuguese The instrument consists of the electronic unit the miniaturised traverse unit incorporated and where applicable a pr...

Page 3: ...n of the items on the top part is as follows 1 2 On off START start measurement STOP stop measurement key 3 Key for displaying the result of the measurement displaying and presetting the cut off and cut off number If pressed when in Liquid crystal display LCD the main menu causes the higher level menu to return on display 4 Scroll key If pressed when the result of a measurement is on display bring...

Page 4: ... shows 1 The results of a measurement 2 The cut off 3 The cut off number 4 An error message To exit from the main menu and the submenus press the and the first one immediately starts the measure the second in the submenus makes to climb a level in the main menu it makes to visualize the parameters The structure of the menu can be seen in the figure that follows The selections made on the submenus ...

Page 5: ...ayed because the assessment of the parameters is strictly related to λc and to the number of λc used When the cut off or cut off number is changed on an instrument already preset for measurement setting of the cut off may be terminated with the key which immediately starts the measuring cycle 4 How to preset the traverse length with ISO 12085 When the ISO 12085 standard is used the measurement ran...

Page 6: ...selection on the item Position and press The following indication will be obtained where the vertical arrow indicates current position of the stylus while the horizontal line below it represents the total excursion of the stylus during the positioning session In order to obtain correct measurements the arrow must be in the centre of the field defined on the display coinciding with the zero point o...

Page 7: ...rated in the examples that follow 11 12 Note if you need to check the value of a disabled parameter and you have just finished measuring simply enable the parameter concerned It is not necessary to complete the measurement The parameter Rmr represents the bearing ratio and it is also graphically printed as curve of Abbott 8 Setting the calculating standard 1 In the main menu make your selection on...

Page 8: ...menu Files Eliminating all the measurements stored 1 In the main menu make your selection on the item Files and press to bring up the submenu 2 Make your selection on the item Reset and press Press to go back to the main menu 16 Operations When performing measurements to get a correct result there are a number of hints that should be observed 1 Where possible place the instrument and the part bein...

Page 9: ... is left connected for more than this time because it is provided with an automatic charge control means It is possible to use the instrument even while the accumulator battery is recharging Note do not store the instrument for long periods with the accumulator battery discharged as it will become damaged If left idle for long periods check the charge level at least once every 30 days If the accum...

Page 10: ... receiver is not programmed correctly c The connection cable is damaged Signalled when the diagnostic checks reveal a memory defect Remedies call the technical service department Signalled at the end of a measurement when with the ISO 12085 standard selected the instrument s calculating capacity is exceeded Probable cause The profile examined cannot be gauged Resetting The Storage Memory If there ...

Reviews: