All  the  settings  are  never  lost  even  after  the  battery  has  been 
completely  discharged  since  the  instrument  uses  a  particular 
MRAM internal storage memory. 
Through  a  data  output  connector  a  link  can  be  made  to  a 
dedicated  printer  or  to  a  computer.  This  connection  can  only  be 
made by using the cables supplied by the manufacturer. With the 
printer connection a header and 3 user-customisable lines can be 
printed;  through  the  computer  link,  and  with  suitable  software,  it 
is  possible  to  control  all  the  functions  of  the  roughness  tester, 
transmit  the  measured  profile  to  the  computer  and  enter  and 
change at will the 3 customizable lines.
The  printout,  in  all  the  envisaged  modes,  can  only  be  produced 
using the keys on the printer (optional).

2

Structure:

The  instrument  can  be  controlled  entirely  using  the  keyboard  on 
the top part of the ISR-S400. Some of the keys perform a function 
directly,  while  others  are  of  assistance  in  handling  menus  and
presettings. The function of some keys will even differ depending 
on  the  context.  With  reference  to  the  figure,  the  main  function  of 
the  items  on  the  top  part  is  as  follows:  The  instrument  can  be 
controlled entirely using the keyboard on the top part of the ISR-
S400.  Some  of  the  keys  perform  a  function  directly,  while  others 
are  of  assistance  in  handling  menus  and  presettings.  The 
function  of  some  keys  will  even  differ  depending  on  the  context. 
With reference to the figure, the main function of the items on the 
top part is as follows:

1. 
2 . O n - o f f  /  S TA R T  ( s t a r t  m e a s u r e m e n t )  -  S T O P  ( s t o p           
measurement) key.
3.  Key  for  displaying  the  result  of  the  measurement  /  displaying 
and presetting the cut-off and cut-off number. If pressed when in 

Liquid crystal display (LCD).

the main menu, causes the higher level menu to return on display.
4.  Scroll  key.  If  pressed  when  the  result  of  a  measurement  is  on 
display,  brings  up  the  parameters  after  those  on  display;  if 
p r e s s e d  w h e n  s e l e c t a b l e  p r e s e t t i n g s  a r e  o n  d i s p l a y,
moves the cursor between the presettings; if pressed when in the 
main menu, moves through the items on the main menu.
5.  “ENTER”  key.  If  pressed  while  the  result  of  a  measurement  or 
the  cut-off  is  on  display,  brings  up  the  main  menu,  otherwise  it 
confirms the selection made.

Auxiliary

 

functions

 

executed

 

by

 

means

 

of

 

the

 

keys

 

will

 

be

 

indicated

 

during

 

the

 

detailed  description

 

of

 

the

 

commands

.

The

 

active

 

selection

 

referred

 

to

 

above

 

is

 

shown

 

on

 

the display

 

by

 

applying

 

a

 

black

 

background to

 

the

 

currently

 

selected

 

item

The

 

function

 

of

 

the

 

selection

 

is

 

to

 

indicate

 

the

 

position

 

of

 

the 

currently

 

active

 

item

 

or

 

of

 

the

 

character

 

on

 

which

 

to

 

take 

action

.

All

 

the

 

keys

 

are

 

provided

 

with

 

self

-

repeating

 

function

that

 

is

 

to

 

say

 

the

 

ability

 

to

 

repeat  their

 

assigned

 

function

 

continuously

 

until

 

such

 

time

 

as

 

they

 

are

 

released

In

 

addition

the

 

key     assumes

 

its

 

second

 

function, that

 

of

 

modifying

 

the

 

digit

 

selected

.

4

top panel

real panel

As  may  be  seen  from  the  figure,  the  following  are  found  on  the 
rear panel:
1. Connector for external power supply.
2. Battery on/off switch.
3. Connector for data output.
4. Connector for printer and for external push-button.

Summary of Contents for ISR-S300

Page 1: ...MN ISR 300 S E www insize com ROUGHNESS TESTER OPERATION MANUAL ISR S300 V0 ...

Page 2: ... a microprocessor it uses an alphanumeric liquid crystal display LCD and the accumulator adopted permits considerable operating autonomy All the messages and menus can be displayed in one of the following five selectable languages Italian English French German Spanish and Portuguese The instrument consists of the electronic unit the miniaturised traverse unit incorporated and where applicable a pr...

Page 3: ...n of the items on the top part is as follows 1 2 On off START start measurement STOP stop measurement key 3 Key for displaying the result of the measurement displaying and presetting the cut off and cut off number If pressed when in Liquid crystal display LCD the main menu causes the higher level menu to return on display 4 Scroll key If pressed when the result of a measurement is on display bring...

Page 4: ... shows 1 The results of a measurement 2 The cut off 3 The cut off number 4 An error message To exit from the main menu and the submenus press the and the first one immediately starts the measure the second in the submenus makes to climb a level in the main menu it makes to visualize the parameters The structure of the menu can be seen in the figure that follows The selections made on the submenus ...

Page 5: ...ayed because the assessment of the parameters is strictly related to λc and to the number of λc used When the cut off or cut off number is changed on an instrument already preset for measurement setting of the cut off may be terminated with the key which immediately starts the measuring cycle 4 How to preset the traverse length with ISO 12085 When the ISO 12085 standard is used the measurement ran...

Page 6: ...selection on the item Position and press The following indication will be obtained where the vertical arrow indicates current position of the stylus while the horizontal line below it represents the total excursion of the stylus during the positioning session In order to obtain correct measurements the arrow must be in the centre of the field defined on the display coinciding with the zero point o...

Page 7: ...rated in the examples that follow 11 12 Note if you need to check the value of a disabled parameter and you have just finished measuring simply enable the parameter concerned It is not necessary to complete the measurement The parameter Rmr represents the bearing ratio and it is also graphically printed as curve of Abbott 8 Setting the calculating standard 1 In the main menu make your selection on...

Page 8: ...menu Files Eliminating all the measurements stored 1 In the main menu make your selection on the item Files and press to bring up the submenu 2 Make your selection on the item Reset and press Press to go back to the main menu 16 Operations When performing measurements to get a correct result there are a number of hints that should be observed 1 Where possible place the instrument and the part bein...

Page 9: ... is left connected for more than this time because it is provided with an automatic charge control means It is possible to use the instrument even while the accumulator battery is recharging Note do not store the instrument for long periods with the accumulator battery discharged as it will become damaged If left idle for long periods check the charge level at least once every 30 days If the accum...

Page 10: ... receiver is not programmed correctly c The connection cable is damaged Signalled when the diagnostic checks reveal a memory defect Remedies call the technical service department Signalled at the end of a measurement when with the ISO 12085 standard selected the instrument s calculating capacity is exceeded Probable cause The profile examined cannot be gauged Resetting The Storage Memory If there ...

Reviews: