Operating Instructions/Troubleshooting

OPERATING INSTRUCTIONS

TO START

1. Check to ensure disposer is free of foreign objects.
2. Ensure power is on.
3. Push start button. Disposer motor will run and water 

will flow into the disposer.

TO STOP

1. Push stop button. Disposer motor and water will stop.

TROUBLESHOOTING

This control center was inspected and tested under 
operating conditions before shipment from the factory. 
In case of trouble, check the items listed below.

A.  Disposer motor will not start and water  

does not flow.

 

1.  No incoming line power, turn line power on.

B.  Disposer motor stops while grinding but water 

continues to flow.

  1.  Disposer is jammed. Press the stop button and 

follow directions for unjamming that were  

supplied with the disposer.

  2.  Disposer motor overload protector has tripped.  

Follow instruction in C1.

C.  Disposer will not start but water flows.

  1.  Overload protector on the disposer may have 

tripped. Press stop button. Locate red reset  

button on front of disposer electrical cover. Press 

to reset. If motor had been running, wait five 

minutes for the motor and overload to cool down 

before starting.

  2.  Disposer is jammed. Press the stop button and 

follow directions for unjamming that were  

supplied with the disposer.

D.  Water flows constantly before start button  

is pushed.

  1.  Water solenoid valve is installed backward.  

Water flow should be in the direction of the  

arrow on valve.

  2.  Water solenoid valve is wired incorrectly.  

Recheck wiring diagram.

E.  Overload trips frequently.

  1.  Do not overload disposer with excess amounts of 

garbage and water. (See disposer instructions for 

recommended water flows.)

If trouble still persists, call your nearest InSinkErator  
Authorized Service Agency. For the location of your 
nearest service agency, call toll-free 1-800-845-8345.

PERSONAL INJURY

 • Allow only trained personnel to operate disposer.
 • Use baffles and guarding to avoid splashing and 

ejection of materials.

 • Do not put fingers or hands into the disposer.
 • When attempting to remove objects from a  

disposer, use long-handled tongs or pliers.

 • Turn power off before clearing a jam, removing  

an object from the disposer or pressing the red 

reset button.

ELECTRICAL SHOCK/PROPERTY DAMAGE

 • Troubleshooting other than what is recommended 

in this section should only be performed by  

qualified service personnel.

 • Further troubleshooting performed by untrained 

personnel could result in electric shock or damage 

to the control center.

 • All electrical checks must be performed by a  

qualified professional.

Summary of Contents for MS MS

Page 1: ...ons contained in this manual The Danger signal indicates an immediately hazardous situation which if not avoided will result in death or serious injury The Warning signal alerts you to potential hazar...

Page 2: ...anty FOODSERVICE DISPOSER CONTROL CENTER LIMITED WARRANTY InSinkErator Foodservice Disposer Control Centers are warranted against defects in material and workmanship for one year from the date of inst...

Page 3: ...4356 120V 1 1 2 2 MS 5 14356A 208 230V 1 1 2 2 MS 5 14356A 208 230V 3 1 2 5 MS 6 14356B 380 460V 3 1 2 10 FEATURES ENCLOSURE NEMA 4 construction PUSH BUTTON OPERATION Push Green button to start dispos...

Page 4: ...upplied is the proper voltage Make certain that the valves are plumbed according to water flow direction arrows marked on valves or the valves will not function properly The flow control valve regulat...

Page 5: ...diagram inside the motor terminal box Make sure the solenoid valve is the same voltage as the control panel and supply power Connect water solenoid valve as shown in the wiring diagrams on pages 7 8 9...

Page 6: ...e stop button and follow directions for unjamming that were supplied with the disposer D Water flows constantly before start button is pushed 1 Water solenoid valve is installed backward Water flow sh...

Page 7: ...enters and disposers must be carefully and permanently grounded A properly fused disconnect must be installed at the electrical supply source for the control center PROPERTY DAMAGE Ensure that the con...

Page 8: ...l centers and disposers must be carefully and permanently grounded A properly fused disconnect must be installed at the electrical supply source for the control center PROPERTY DAMAGE Ensure that the...

Page 9: ...s and disposers must be carefully and permanently grounded A properly fused disconnect must be installed at the electrical supply source for the control center PROPERTY DAMAGE Ensure that the control...

Page 10: ...rs and disposers must be carefully and permanently grounded A properly fused disconnect must be installed at the electrical supply source for the control center PROPERTY DAMAGE Ensure that the control...

Reviews: