Features/Mounting the Control Center

3

INTRODUCTION

The MS Control Center is UL

®

 and CUL

®

 approved for 

use with InSinkErator Foodservice Disposers. See  
Table 1 for approved disposer and control center  
combinations. The control center operates the disposer. 
Its main functions are:
•  To start and stop the disposer.
•  To start the water flow to the disposer.

Model

Waste Disposer Model

MS-4
MS-5

SS50-26, SS75-27, SS100-28, SS125-25, 

SS150-34, SS150-38, SS200-27, SS200-31

MS-5

SS50-27, SS75-28, SS100-29,  

SS125-26, SS150-36, SS150-39,  

SS200-29, SS200-32, SS300-25, SS300-27, 

SS500-28, SS500-29, SS500-30

MS-6

SS50-27, SS75-28, SS100-29,  

SS125-26, SS150-36, SS150-39,  
SS200-29, SS200-32, SS300-25,  

SS300-27, SS500-28, SS500-30, SS750-13, 

SS750-15, SS1000-10, SS1000-11, SS1000-12

Model

Part No.

Voltage

Phase

HP

MS-4

14356

120V

1

1/2-2

MS-5

14356A

208-230V

1

1/2-2

MS-5

14356A

208-230V

3

1/2-5

MS-6

14356B

380/460V

3

1/2-10

FEATURES 

ENCLOSURE

 

NEMA 4 construction.

PUSH BUTTON OPERATION

Push Green button to start disposer. Push Red button to 
stop disposer.

PROPERTY DAMAGE

Use of more than two solenoid valves will affect 

the overall function of the MS control center. Extra 

solenoid valves will cause a reduction in voltage and 

solenoid actuation will not occur.

Table 1.  Approved Disposer and Control Center Combinations

Table 2. Electrical Specifications

MOUNTING THE CONTROL CENTER

Use the flanges at the back of the control center  
enclosure and only mount panel in the upright vertical 
position. See Figure 1.

Locate control center within sight of disposer per local 
codes. Locate any remote control station within sight of 
disposer per local codes.

If box is mounted to the sink table, recess the box so 
that the buttons do not extend beyond the table's edge.

Figure 1. Control Center Dimensions

Summary of Contents for MS MS

Page 1: ...ons contained in this manual The Danger signal indicates an immediately hazardous situation which if not avoided will result in death or serious injury The Warning signal alerts you to potential hazar...

Page 2: ...anty FOODSERVICE DISPOSER CONTROL CENTER LIMITED WARRANTY InSinkErator Foodservice Disposer Control Centers are warranted against defects in material and workmanship for one year from the date of inst...

Page 3: ...4356 120V 1 1 2 2 MS 5 14356A 208 230V 1 1 2 2 MS 5 14356A 208 230V 3 1 2 5 MS 6 14356B 380 460V 3 1 2 10 FEATURES ENCLOSURE NEMA 4 construction PUSH BUTTON OPERATION Push Green button to start dispos...

Page 4: ...upplied is the proper voltage Make certain that the valves are plumbed according to water flow direction arrows marked on valves or the valves will not function properly The flow control valve regulat...

Page 5: ...diagram inside the motor terminal box Make sure the solenoid valve is the same voltage as the control panel and supply power Connect water solenoid valve as shown in the wiring diagrams on pages 7 8 9...

Page 6: ...e stop button and follow directions for unjamming that were supplied with the disposer D Water flows constantly before start button is pushed 1 Water solenoid valve is installed backward Water flow sh...

Page 7: ...enters and disposers must be carefully and permanently grounded A properly fused disconnect must be installed at the electrical supply source for the control center PROPERTY DAMAGE Ensure that the con...

Page 8: ...l centers and disposers must be carefully and permanently grounded A properly fused disconnect must be installed at the electrical supply source for the control center PROPERTY DAMAGE Ensure that the...

Page 9: ...s and disposers must be carefully and permanently grounded A properly fused disconnect must be installed at the electrical supply source for the control center PROPERTY DAMAGE Ensure that the control...

Page 10: ...rs and disposers must be carefully and permanently grounded A properly fused disconnect must be installed at the electrical supply source for the control center PROPERTY DAMAGE Ensure that the control...

Reviews: