background image

2

Table of Contents

Introduction/Features

 

Introduction ......................................................................................3

 

Features .......................................................................................... 3

 

Mounting the Control Center .......................................................... 3

Plumbing Connections

  ................................................................................. 4

Electrical Connections

 

Electrical Connections .................................................................... 5

 

Time Delay Relay ............................................................................. 5

Operating Instructions/Troubleshooting

 

Operating Instructions  .................................................................... 6

 

Troubleshooting  .............................................................................. 6

Wiring Diagrams

 

Model No. MS-4 (120V, 1 phase, 1/2-2 HP) .................................... 7

 

Model No. MS-5 (208-230V, 1 phase, 1/2-2 HP) ............................ 8

 

Model No. MS-5 (208-230V, 3 phase, 1/2-5 HP) ............................ 9

 

Model No. MS-6 (380/460V, 3 phase, 1/2-10 HP) ......................... 10

Warranty

FOODSERVICE DISPOSER CONTROL CENTER LIMITED WARRANTY

InSinkErator Foodservice Disposer Control Centers are warranted against defects in material and workmanship for 
one year from the date of installation. The warranty includes parts and labor, provided the service is performed by an 
InSinkErator Factory Authorized Service Center. This warranty does not apply if failure is due to: 

faulty or improper 

electrical installation, faulty or improper plumbing installation, product abuse or misuse, or accidental damage.

InSinkErator Foodservice disposer accessories are included in this warranty only if they are included in the original 
disposer purchase package.

Summary of Contents for MS MS

Page 1: ...ons contained in this manual The Danger signal indicates an immediately hazardous situation which if not avoided will result in death or serious injury The Warning signal alerts you to potential hazar...

Page 2: ...anty FOODSERVICE DISPOSER CONTROL CENTER LIMITED WARRANTY InSinkErator Foodservice Disposer Control Centers are warranted against defects in material and workmanship for one year from the date of inst...

Page 3: ...4356 120V 1 1 2 2 MS 5 14356A 208 230V 1 1 2 2 MS 5 14356A 208 230V 3 1 2 5 MS 6 14356B 380 460V 3 1 2 10 FEATURES ENCLOSURE NEMA 4 construction PUSH BUTTON OPERATION Push Green button to start dispos...

Page 4: ...upplied is the proper voltage Make certain that the valves are plumbed according to water flow direction arrows marked on valves or the valves will not function properly The flow control valve regulat...

Page 5: ...diagram inside the motor terminal box Make sure the solenoid valve is the same voltage as the control panel and supply power Connect water solenoid valve as shown in the wiring diagrams on pages 7 8 9...

Page 6: ...e stop button and follow directions for unjamming that were supplied with the disposer D Water flows constantly before start button is pushed 1 Water solenoid valve is installed backward Water flow sh...

Page 7: ...enters and disposers must be carefully and permanently grounded A properly fused disconnect must be installed at the electrical supply source for the control center PROPERTY DAMAGE Ensure that the con...

Page 8: ...l centers and disposers must be carefully and permanently grounded A properly fused disconnect must be installed at the electrical supply source for the control center PROPERTY DAMAGE Ensure that the...

Page 9: ...s and disposers must be carefully and permanently grounded A properly fused disconnect must be installed at the electrical supply source for the control center PROPERTY DAMAGE Ensure that the control...

Page 10: ...rs and disposers must be carefully and permanently grounded A properly fused disconnect must be installed at the electrical supply source for the control center PROPERTY DAMAGE Ensure that the control...

Reviews: