background image

ELECTRICAL CONNECTIONS - AQUA-SAVER 

 

 

FIGURE 14. Connection diagram CC-101K-1Ø to Aqua-Saver and disposer (120V) 

 

FIGURE 15. Connection diagram CC-101K-1Ø to Aqua-Saver and disposer (230V) 

8

 

 

Summary of Contents for CC-101K

Page 1: ...es which could result in severe personal injury or death Cautions alert you to hazards or unsafe practices which could result in personal injury or property damage Please be certain that the person wh...

Page 2: ...HE CONTROL CENTER 3 PLUMBING CONNECTIONS 3 PLUMBING CONNECTIONS AQUA SAVER 4 ELECTRICAL CONNECTIONS 5 ELECTRICAL CONNECTIONS AQUA SAVER 6 8 OPERATING INSTRUCTIONS 9 OPERATING INSTRUCTIONS AQUA SAVER 1...

Page 3: ...f the water continues to flow for up to 10 minutes The length of this post flush is controlled by the water shutoff delay timer The post flush helps ensure that ground food waste is flushed out of the...

Page 4: ...valve and syphon breaker are supplied with ad complete disposer packages packed separately The solenoid valve is supplied with a 24 V coil Make certain that the valves are plumbed according to water...

Page 5: ...Figure 3 shows the recommended installation for an Aqua Saver System Construct solenoid valve flow control manifold as shown in Figure 4 FIGURE 4 Solenoid valve flow control manifold TABLE 3 Horsepowe...

Page 6: ...on power CAUTION PROPERTY DAMAGE Ensure that control center voltage and phase match the disposer motor and electrical supply Check name plates on disposer and control centers for voltage and phase spe...

Page 7: ...nected to the CC101K must use the one gallon per minute flow control valve Figures 9 10 and 11 illustrate the connections of the solenoid valve to the Aqua Saver Figures 12 13 14 and 15 illustrate con...

Page 8: ...ELECTRICAL CONNECTIONS AQUA SAVER FIGURE 12 Connection diagram CC 101K 3 to Aqua Saver and disposer 208 230V FIGURE 13 Connection diagram CC 101K 3 to Aqua Saver and disposer 460V 7...

Page 9: ...ELECTRICAL CONNECTIONS AQUA SAVER FIGURE 14 Connection diagram CC 101K 1 to Aqua Saver and disposer 120V FIGURE 15 Connection diagram CC 101K 1 to Aqua Saver and disposer 230V 8...

Page 10: ...START 1 Check to ensure disposer is free of foreign objects 2 Ensure power is on 3 Push start button Disposer motor will run and water will flow into the disposer TO STOP 1 Push stop button Disposer m...

Page 11: ...of time the water runs at full flow after grinding is completed Mid setting is approximately 15 seconds 2 With the disposer running but not grinding a Adjust the trip point control to maximum positio...

Page 12: ...check the items listed below A Disposer motor will not start and water does not flow 3 Disposer motor or control center wires may be improperly connected Recheck wiring diagram on page 12 13 14 or 15...

Page 13: ...s must be carefully and permanently grounded A property fused disconnect must be installed at the electrical supply source for the control center CAUTION PROPERTY DAMAGE Ensure that the control center...

Page 14: ...s must be carefully and permanently grounded A properly fused disconnect must be installed at the electrical supply source for the control center CAUTION PROPERTY DAMAGE Ensure that the control center...

Page 15: ...s must be carefully and permanently grounded A properly fused disconnect must be installed at the electrical supply source for the control center CAUTION PROPERTY DAMAGE Ensure that the control center...