Chapter 4 Parameters
- 50 -
Parameter No. Parameter Name
Setting Range
Default Unit Property
F3-19
Traffic mode setting
for period 5
0: Energy-saving mode
1: Normal traffic mode
2: Up peak mode
3: Down peak mode
4: Sudden peak hour mode
1
-
☆
F3-20
Floors with peak
traffic in period 5
0–56
1
-
☆
F3-21
Start time of period 6
Start time of period 6 in traffic
mode
00.00
-
☆
F3-22
End time of period 6
Start time of period 6 in traffic
mode
00.00
-
☆
F3-23
Traffic mode setting
for period 6
0: Energy-saving mode
1: Normal traffic mode
2: Up peak mode
3: Down peak mode
4: Sudden peak hour mode
1
-
☆
F3-24
Floors with peak
traffic in period 6
0–56
1
-
☆
F3-25
Start time of period 7
Start time of period 7 in traffic
mode
00.00
-
☆
F3-26
End time of period 7
Start time of period 7 in traffic
mode
00.00
-
☆
F3-27
Traffic mode setting
for period 7
0: Energy-saving mode
1: Normal traffic mode
2: Up peak mode
3: Down peak mode
4: Sudden peak hour mode
1
-
☆
F3-28
Floors with peak
traffic in period 7
0–56
1
-
☆
F3-29
Start time of period 8
Start time of period 8 in traffic
mode
00.00
-
☆
F3-30
End time of period 8
Start time of period 8 in traffic
mode
00.00
-
☆
F3-31
Traffic mode setting
for period 8
0: Energy-saving mode
1: Normal traffic mode
2: Up peak mode
3: Down peak mode
4: Sudden peak hour mode
1
-
☆
F3-32
Floors with peak
traffic in period 8
0–56
1
-
☆
F3-33
Start time of period 9
Start time of period 9 in traffic
mode
00.00
-
☆
F3-34
End time of period 9
Start time of period 9 in traffic
mode
00.00
-
☆