8.4
DIGITAL I/O CONFIGURATION
8.4.1
DRIVES DIGITAL I/O CONFIGURRATION
Function
code
Name
Setting Range
Meaning
F4-00
DI1 hardware
source selection
0: no choice
1: Rectifier-DI1
2: Rectifier-DI2
3: Rectifier-DI3
4: Rectifier-DI4
5: Rectifier-DIO1
6: Rectifier-DIO2
7: Rectifier-DIO3
8: Rectifier-DIO4
101: Expansion card 1-DI1
102: Expansion card 1-DI2
103: Expansion card 1-DI3
104: Expansion card 1-DI4
105: Expansion card 1-DI5
106: Expansion card 1-DI6
107: Expansion card 1-DI7
108: Expansion card 1-DI8
201: Expansion card 2-DI1
202: Expansion card 2-DI2
203: Expansion card 2-DI3
204: Expansion card 2-DI4
205: Expansion card 2-DI5
206: Expansion card 2-DI6
207: Expansion card 2-DI7
208: Expansion card 2-DI8
Select the source of the input
terminal.
F4-01
DI1 terminal
function selection
0-63. See table below
Select the function of the input
terminal.
F4-02
DI2 hardware
source selection
See function code F4-00
setting range
Select the source of the input
terminal.
F4-03
DI2 terminal
function selection
0-63. See table below
Select the function of the input
terminal.
F4-04
DI3 hardware
source selection
See function code F4-00
setting range
Select the source of the input
terminal.
F4-05
DI3 terminal
function selection
0-63. See table below
Select the function of the input
terminal.
F4-06
DI4 hardware
source selection
See function code F4-00
setting range
Select the source of the input
terminal.
F4-07
DI4 terminal
function selection
0-63. See table below
Select the function of the input
terminal.
F4-08
DI5 hardware
source selection
See function code F4-00
setting range
Select the source of the input
terminal.
F4-09
DI5 terminal
function selection
0-63. See table below
Select the function of the input
terminal.
F4-10
DI6 hardware
source selection
See function code F4-00
setting range
Select the source of the input
terminal.