HID
08:30
18:30
FOLLOW
60%
Type:
LED
ON at:
08:00
OFF at:
18:00
MODE:
Auto
OUTPUTMAX:
80%
1.73
VPD
CHANNEL 1 CHANNEL 2
28.5
℃
Heat:
15.0
℃
Cool:
35.0
℃
Deadband:
5.0
℃
LIGHT
TEMP
Protection:
High CO2 PPM
5000
1100
Target:
1200
Deadband:
200
44.7
%RH
Humidify:
30
%RH
Dehumidify:
90
%RH
Deadband:
5
%RH
CO
2
PPM
CLIMATE
HUMI
SYSTEM
IRRIGATION
SETTING
STATUS
CONNECTION
STATUS
10:49:05
11-01-2020
Daytime Mode
8. Light Setting
On the home page, the current type of the light and the status of each channel.
The device is provided with two light channels, each of which can be connected to 20 light dimming
adapter (LDA-1) modules at most to control the HID or LED lamps.
The channel 1 is set for the main line light control, and the channel 2 light is set for the auxiliary line
light control.
(8.1) Channel 1 setting
The light parameters to be set are listed below:
[LIGHT MODE]
: LED, HID;
[ON Time at]
: 8:00;
[HID Delay]
: 3min ~ 180min;
[Sun R/S]
: 0 ~ 60min;
[OFF TEMP]
:
10.0
℃
~ 70
℃
;
50~158°F
[Output Max]
: 50% ~ 115%;
[OFF Time at]
: 18:00;
[Mode]
: LIGHT AUTO MODE, LIGHT SET MODE
and MANUAL MODE;
[DIM TEMP]
for 50% overheat:10.0
℃
~ 70
℃
;
50~158°F
31