Innovative THEPROTECTOR C-1 Instruction Manual Download Page 27

6. Humidity parameter setting interface

In the humidity parameter setting interface, the current real-time data and the working status of the
device are displayed in the upper part.

If the device is not equipped with temperature and humidity module, the relevant data of temperature,
humidity and CO

2

three-in-one module can be used; meanwhile, the humidity parameters of the

device will be displayed, such as working mode, low humidity protection value, high humidity protec-
tion value, target value, and deadband value.

After the data are set, the Save button will light up. At this time, press the Save button to save the data,
after which a dialogue box will pop up prompting you to save the data; the data modified will not take
effect unless they are saved.

(6.1) Humidity Setting

In this section, you can set the target value in the box behind [Humidify], target value in the box
behind [Dehumidify], deadband value in the box behind [Deadband], low humidity protection value

in the box behind [Low Humi Protection], high humidity protection value in the box behind [High
Humi Protection] respectively in the day and night mode.

26

Summary of Contents for THEPROTECTOR C-1

Page 1: ...MASTER ENVIRONMENTAL CONTROL C 1 MASTER ENVIRONMENTAL CONTROL C 1 Instruction Manual...

Page 2: ...of MASTER ENVIRONMENTAL CONTROL C 1 II Specifications of MASTER ENVIRONMENTAL CONTROL C 1 III Warnings Cautions IV Installation Instructions V Installation Diagram VI Interface Instructions VII Opera...

Page 3: ...be controlled and can simultaneously employ 2 channels of independent or interlocked light control logic in different modes to create multiple lighting layouts and growth spectra required for plant gr...

Page 4: ...485 communication Signal line output DC24V 1 0A Operating Environment 5 to 40 Relative humidity 80 no frosting Indoor Use Only Network port RJ45 Dimensions 14 H x 17 W x 4 D excluding length of power...

Page 5: ...orking voltage DC24V Working current 30mA CO2 range 0 6000ppm CO2 accuracy 30ppm 3 Humidity range 0 100 RH Humidity accuracy 2 RH Temperature range 32 158 F 0 70 Temperature accuracy 32 9 F 0 5 Maximu...

Page 6: ...Indicator Green LED Maximum connections quantity 32pcs Communication Mode RS485 Modbus RTU Main parameters Default values Input Voltage DC24V Output Voltage 0 10V DC Communication terminal RJ12 conne...

Page 7: ...supply DC 24V Output RS485 Range 0 5m water column Pressure type Gauge Pressure Compensation temperature 14 158 F 10 70 Operating temperature 4 185 F 20 85 Medium temperature 4 185 F 20 85 Storage te...

Page 8: ...with the parameter described After the equipment is installed perform the start up test before operating it properly DO NOT use this controller near a water source The controller is not water proof or...

Page 9: ...e Master Environmental Control C 1 Please install the controller at the place you are easily work with You need to leave some space for air ventilation use Please keep controller away from flammable a...

Page 10: ...Method 1 Connecting a single device 2 Sensor Connection Instructions Connect the sensor module to the Sensor port Connect more Y splitter 3 Devices Connection Instructions Connect the devices module t...

Page 11: ...d 2 Multiple lighting module are connected through the Y Splitter branch Connect more Y splitter Method 2 Multiple devices are connected through the Y splitter branch CO2 Generator 4 Lighting Equipmen...

Page 12: ...bottom of the controller and lock it tightly Then pass the equipment signal line through the PVC pipe lock the terminal and then insert the terminal into the corresponding identification interface in...

Page 13: ...e consistent set the required parameters on the properly before using it 2 The operation status of controller will be displayed on the screen lease learn each signal well before using 3 Make sure that...

Page 14: ...IV Installation Diagram Devices CO2 Generator CO2 Tank Fan Lights 4x Humidity Temp Sensor Lights 4x CO2 Sensor Net Power AC 110V USB TF Reset Dehumidifier Distribution box Devices 13...

Page 15: ...r needs to consider the number of sensors and related devices that need to be equipped based on the actual conditions of the planting area for the heavy current 110V 380V devices in the circuits shoul...

Page 16: ...SETTING STATUS CONNECTION STATUS 10 49 05 11 01 2020 Daytime Mode V Interface Instructions Turn on the controller the loading interface will be shown directly on the display After the loading is compl...

Page 17: ...and dehumidify control mode and idle mode After analysis of the humidity data read by the sensor the humidity in the environment can be controlled and adjusted The humidity is controlled within a ran...

Page 18: ...r Environmental Control C 1 controller will display the date symbol in the upper left corner of the day night mode Day mode control The Master Environmental Control C 1 controller outputs signals to t...

Page 19: ...atic liquid dispensing switch and high water temperature alarm can be set VI Operation Instructions 1 Power on Turn on the the LOGO will be automatically displayed in the interface waiting for the dat...

Page 20: ...n navigate to other related interfaces via the interface on the right side Time format Set the date format as MM DD YYYY and the time format as HH MM SS 12 24 hour time format 12 hour and 24 hour time...

Page 21: ...D connection status online offline will be displayed simultaneously In this interface you can choose to find unregistered devices 2 2 Adding sensors or devices In this interface you can delete or find...

Page 22: ...evice list The RS485 port for the sensor is the Sensor port The RS485 port for the device is the Device port The RS485 port for the LDA 1 device is the Light LINE 1 or Light LINE 2 port 2 3 Deleting s...

Page 23: ...en registered but not connected the status indicator will be red 4 Home Page In the Home Page the real time data of VPD humidity temperature and CO2 are displayed In the upper left corner the humidity...

Page 24: ...49 05 11 01 2020 Daytime Mode 5 CO2 Setting In the CO2 setting interface the real time data of the currently connected sensor are displayed as well as the device s CO2 parameters set such as working m...

Page 25: ...O2 PPM protection value High CO2 PPM Protection value The value shall be lower than 9999 and the target value needs to be higher than the CO2 target value When the value entered exceeds the setting ra...

Page 26: ...rrent working status display When performing actions the current device will display the specific working status of the device In different modes different icons are used to display the current workin...

Page 27: ...umidity protec tion value target value and deadband value After the data are set the Save button will light up At this time press the Save button to save the data after which a dialogue box will pop u...

Page 28: ...otection value The value set needs to be lower than the Humidify target value High Humi Protection value The value set needs to be higher than the Dehumidify target value After the Humidify Deadband v...

Page 29: ...vice are displayed in the upper part of the device If the device is not equipped with a temperature and humidity module the relevant temperature and humidity data of the 3 in 1 module will be used Mea...

Page 30: ...and the cooling is started The target value set needs to be higher than the low temperature protection value plus the deadband value and needs to be lower than the high temperature protection value De...

Page 31: ...on output port when the current value is lower than Heat value and immediately turn off the heating output port when the real time tempera ture value is higher than Heat Deadband value The device will...

Page 32: ...of the light and the status of each channel The device is provided with two light channels each of which can be connected to 20 light dimming adapter LDA 1 modules at most to control the HID or LED l...

Page 33: ...interface when the device is turned off the delay time required to wait for the response is enabled again which is from 3min to 180min 8 4 Sun r s parameter setting In the interface the Sun R S mode c...

Page 34: ...10 0 70 50 158 F following the main line setting 8 6 Following mode of auxiliary line light following the main line setting In the following mode of auxiliary line light the relevant parameters of the...

Reviews: