background image

owner

s manual 

Symptom 4: Noise of air conditioners cooling  

Symptom 4.1: Indoor unit 

When humidity is high during cooling operation If the interior of 
an  indoor  unit  is  extremely  contaminated,  the  temperature 
distribution  inside  a  room  becomes  uneven.  It  is  necessary  to 
clean  the  interior  of  the  indoor  unit. Ask  your  dealer  for  details 
on cleaning the unit. This operation requires a qualified service 
person. 

When  the  system  is  changed  over  to  heating  operation  after 
defrost  operation  Moisture  generated  by  defrost  becomes 
steam and is exhausted.   

A  continuous  low  "shah"  sound  is heard  when  the  system  is  in 
cooling operation or at a stop.  
When the drain pump (optional accessories) is in operation,this 
noise is heard. 
 
A "pishi-pishi" squeaking sound is heard when the system stops 
after heating operation.  
Expansion  and  contraction  of  plastic  parts  caused  by 
temperature change make this noise.  

Symptom 4.2:  Indoor unit, outdoor unit  

A continuous low hissing sound is heard when the system is in 
operation.  
This is the sound of refrigerant gas flowing through both indoor 
and outdoor units.  

A continuous low hissing sound is heard when the system is in 
operation.  
This is the sound of refrigerant gas flowing through both indoor 
and outdoor units.  
 
A hissing sound which is heard at the start or immediately after 
stopping operation or defrost operation.  
This  is  the  noise  of  refrigerant  caused  by  flow  stop  or  flow 
change.  

Symptom 4.3: Outdoor unit  

When the tone of operating noise changes.  
This noise is caused by the change of frequency. 

 

The operation lamp is flashing rapidly (5Hz). 
This lamp is still flashing rapidly after turn off the power and turn 
on again. (See in Table 8-1 and Table 8-2) 
 
Remote  controller  receives  malfunction  or  the  button  does  not 
work well. 
 
A safety device such as a fuse, a breaker frequently actuates. 
 
Obstacles and water enter the unit. 
 
Water leaks from indoor unit. 
 
Other malfunctions. 

8.    TROUBLESHOOTING 

If one of the following malfunctions occur, stop operation, shut 
off the power, and contact with your dealer. 

If  the  system  does  not  properly  operate  except  the  above 
mentioned  cases  or  the  above  mentioned  malfunctions  is 
evident,  investigate  the  system  according  to  the  following 
procedures. 

(See in Table 8-3) 

 

 

8.1    Troubles and causes of air conditioner

Symptom 5: Dust comes out of the unit  

Symptom 6: The units can give off odours 

When the unit is used for the first time in a long time.  
This is because dust has gotten into the unit. 

The  unit  can  absorb  the  smell  of  rooms,  furniture,  cigarettes, 
etc., and then emit it again.  

Symptom 7: The outdoor unit fan does not spin. 

During operation. The speed of the fan is controlled in order to 
optimize product operation.  

8.2    Troubles and causes of remote controller

Before asking for serving or repairing, check the following points. 
 

(See in Table 8-4) 

7.    FOLLOWING SYMPTOMS ARE NOT AIR 

       CONDITIONER TROUBLES 

Symptom 1: The system does not operate 

Symptom 2: Change into the fan mode during cooling   
                      mode 

Symptom 3: White mist comes out of a unit 

The air conditioner does not start immediately after the ON/OFF 
button on the romote controller is pressed.  
If the operation lamp lights, the system is in normal condition.To 
prevent  overloading  of  the  compressor  motor,  the  air 
conditioner starts 3 minutes  after  it  is turned ON. 
 
If  the  operation  lamp  and  the  "PRE-DEF  indicator(cooling  and 
heating  type)  or  fan  only  indicator(cooling  only  type)"  light,  it 
means you choose the heating model, When just starting, if the 
compressor has not started, the indoor unit  appears "anti cold 
wind" protection because of its overlow outlet temperature. 

In  order  to  prevent  the  indoor  evaporator  frosting,  the  system 
will  change  into  fan  mode  automatically,  restore  to  the  cooling 
mode after soon. 
 
When  the  room  temperature  drops  to  the  set  temperature,  the 
compressor goes off and the indoor unit changes to  fan mode; 
when  the temperature rises up,  the  compressor  starts again. It 
is same in the heating mode. 

Symptom 3.1: Indoor unit 

Symptom 3.2:  Indoor unit, outdoor unit 

When humidity is high during cooling operation If the interior of 
an  indoor  unit  is  extremely  contaminated,  the  temperature 
distribution  inside  a  room  becomes  uneven.  It  is  necessary  to 
clean  the  interior  of  the  indoor  unit. Ask  your  dealer  for  details 
on cleaning the unit. This operation requires a qualified service 
person 

Summary of Contents for ICS0629C21

Page 1: ... Cassette Type OWNER S MANUAL Thank you very much for purchasing our air conditioner Before using your air conditioner please read this manual carefully and keep it for future reference ICS0629C21 ICS0736C21 ICS0848C21 ...

Page 2: ...te controller Air outlet Refrigerant pipe Air filter inside air in grill Air inlet Air inlet Air inlet Air outlet 3 9 10 10 11 11 11 11 11 11 12 12 12 All the pictures in this manual are for explanation purpose only They may be slightly different from the air conditioner you purchased depend on model The actual shape shall prevail NOTE OR 10 11 1 5 7 8 2 4 6 Fig 1 ...

Page 3: ...connection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundeater and get into the food chain damaging your health and well being To prevent refrigerant leak contact your dealer When the system is installed and runs in a small room it is required to keep the concentration of the refrigerant if by any chance coming out bel...

Page 4: ... without supervision This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance If the suppl...

Page 5: ...se in the cooling or heating effect Never place objects near the air inlet or the air outlet of the unit It may cause deterioration in the effect or stop the operation Set the timer If you don t plan to use the unit for a long time please take the batteries from the remote controller When the power is on some energy will be consumed even if the air conditioner isn t in operation So please disconne...

Page 6: ... the air filter shown in Fig 6 1 Pull the air in grill down at 45 and lift it up to take out the grill Dismantle the air filter Clean the air filter Vacuum cleaner or pure water may be used to clean the air filter If the dust accumulation is too heavy please use soft brush and mild detergent to clean it and dry out in cool place The air in side should face up when using vacuum cleaner See Fig 6 3 ...

Page 7: ...erly operate except the above mentioned cases or the above mentioned malfunctions is evident investigate the system according to the following procedures See in Table 8 3 8 1 Troubles and causes of air conditioner Symptom 5 Dust comes out of the unit Symptom 6 The units can give off odours When the unit is used for the first time in a long time This is because dust has gotten into the unit The uni...

Page 8: ...Quick flash E1 10 11 Indoor master slave unit communication checking channel is abnormal F3 Quick flash Quick flash Other malfunctions of master slave unit F4 Quick flash Quick flash Outdoor unit malfunction Ed Slow flash Collision model malfunction E0 Quick flash Table 8 2 Applicable to fixed frequency air conditioner only NO Malfunction running lamp timer lamp defrosting lamp alarm lamp 1 2 3 4 ...

Page 9: ...ing gas in the refrigerating circuit Compressor is malfunction Voltage is too high or too low System circuit is blocked Outdoor unit and indoor unit heat exchanger is dirty The air filter is dirty Inlet outlet of indoor outdoor units is blocked Doors and windows are open Sunlight directly shine Too much heat resource Outdoor temp is too high Leakage of refrigerant or lack of refrigerant Wait for t...

Page 10: ...emote controller is properly directed to the infrared signal receiver of the indoor unit when the ON OFF button is pressed Directly transmit the signal transmitter of the remote controller to the infrared signal receiver of the indoor unit and then repeatly push the ON OFF button twice The indication on the display disappears after a lapse of time Check whether the timer operation has come to an e...

Page 11: ...QS01U 007AW 202000171405 20130618 The design and s pecifications ar e subject to change without pr ior no tice for product improv ement Consult with the s ales agency or manufacturer for details ...