background image

owner

s manual 

6.    MAINTENANCE 

CAUTION 

Before  you  clean  the  air  conditioner,  be  sure  the  power 
supply is off. 

Check if the wiring is not broken off or disconnected. 
 
Use  a  dry  cloth  to  wipe  the  indoor  unit  and  remote 
controller.

 

 

A  wet  cloth  may  be  used  to  clean  the  indoor  unit  if  it  is 
very dirty.

 

 

Never use a damp cloth on the remote controller.

 

 

Do not use a chemically-treted duster for wiping or leave 
such material on the unit for long. 

it may damage or fade the surface of the unit. 
 

Do not use benzine, thinner, polishing powder, or similar 
solvents for cleaning.

  

These may cause the plastic surface to crack or deform. 

Cleaning the air filter 

The  air  filter  can  prevent  the  dust  or  other  particulate  from 
going  inside.

 

In  case  of  blockage  of  the  filter,  the  working 

efficiency of the air conditioner may greatly decrease . 
Therefore, the filter must be cleaned once two weeks during 
long time usage. 
 
If the air conditioner is installed in a dust place, clean the air 
filter frequent. 
 
If  the  accumulated  dust  is  too  heavy  to  be  cleaned,  please 
replace  the  filter  with  a  new  one(replaceable  air  filter  is  an 
optional fitting). 

Open the air-in grill 

 

    Push the grill switches towards the middle simultaneously as 
    indicated in 

Fig.6-1

. Then pull down the air-in grill.  

The  control  box  cables  ,which  are  originally  connected  with 
the main body electrical terminators must be pulled off before 
doing as indicated above. 

Take out the air-in grill (together with the air filter shown in 

Fig.6-1

).

 

    Pull the air-in grill down at 45  and lift it up to take out the 
    grill. 
 

Dismantle the air filter.

 

 

Clean the air filter 

    Vacuum cleaner or pure water may be used to clean the air 
    filter.If the dust accumulation is too heavy , please use soft 
    brush and mild  detergent to clean it and dry out in cool place. 

The air-in side should face up when using vacuum cleaner. 

(

See Fig. 6-3

)

 

The air-in side should face down when using water.  

(

See Fig. 6-4

)

 

Re-install the air filter. 
 
Install and close the air-in grill in the reverse order of step 1 
and  2  and  connect  the  control  box  cables  to  the 
corresponding terminators of the main body .     

Fig.6-1 

Fig.6-2 

Fig.6-3 

Fig.6-4 

Do not dry out the air filter under direct sunshine or with  
fire. 

CAUTION 

Maintenance after a long stop period 

 

(eg. at the beginning of the season)

  

Maintenance before a long stop period

  

(eg. at the end of the season)

          

Check  and  remove  everything  that  might  be  blocking  inlet 
and outlet vents of indoor units and outdoor units. 
 
Clean air filters and casings of indoor units.  
Refer to "Cleaning the air filter" for details on how  to proceed 
and  make  sure  to  install cleaned air  filters  back in  the same 
position.  
 
Turn on the power at least 12 hours before operating the unit 
in order to ensure smoother operation. As soon as he power 
is turned on, the remote controller  displays appear. 

Let the indoor units run in fan only operation for about half a 
day in order to dry the interior of the units. 
 
Clean  air  filters  and  casings  of  indoor  units.  Refer  to  " 
Cleaning  the  air  filter"  for  details  on  how  to  proceed  and 
make  sure  to  install  cleaned  air  filters  back  in  the  same 
position.  

Summary of Contents for ICS0629C21

Page 1: ... Cassette Type OWNER S MANUAL Thank you very much for purchasing our air conditioner Before using your air conditioner please read this manual carefully and keep it for future reference ICS0629C21 ICS0736C21 ICS0848C21 ...

Page 2: ...te controller Air outlet Refrigerant pipe Air filter inside air in grill Air inlet Air inlet Air inlet Air outlet 3 9 10 10 11 11 11 11 11 11 12 12 12 All the pictures in this manual are for explanation purpose only They may be slightly different from the air conditioner you purchased depend on model The actual shape shall prevail NOTE OR 10 11 1 5 7 8 2 4 6 Fig 1 ...

Page 3: ...connection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundeater and get into the food chain damaging your health and well being To prevent refrigerant leak contact your dealer When the system is installed and runs in a small room it is required to keep the concentration of the refrigerant if by any chance coming out bel...

Page 4: ... without supervision This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance If the suppl...

Page 5: ...se in the cooling or heating effect Never place objects near the air inlet or the air outlet of the unit It may cause deterioration in the effect or stop the operation Set the timer If you don t plan to use the unit for a long time please take the batteries from the remote controller When the power is on some energy will be consumed even if the air conditioner isn t in operation So please disconne...

Page 6: ... the air filter shown in Fig 6 1 Pull the air in grill down at 45 and lift it up to take out the grill Dismantle the air filter Clean the air filter Vacuum cleaner or pure water may be used to clean the air filter If the dust accumulation is too heavy please use soft brush and mild detergent to clean it and dry out in cool place The air in side should face up when using vacuum cleaner See Fig 6 3 ...

Page 7: ...erly operate except the above mentioned cases or the above mentioned malfunctions is evident investigate the system according to the following procedures See in Table 8 3 8 1 Troubles and causes of air conditioner Symptom 5 Dust comes out of the unit Symptom 6 The units can give off odours When the unit is used for the first time in a long time This is because dust has gotten into the unit The uni...

Page 8: ...Quick flash E1 10 11 Indoor master slave unit communication checking channel is abnormal F3 Quick flash Quick flash Other malfunctions of master slave unit F4 Quick flash Quick flash Outdoor unit malfunction Ed Slow flash Collision model malfunction E0 Quick flash Table 8 2 Applicable to fixed frequency air conditioner only NO Malfunction running lamp timer lamp defrosting lamp alarm lamp 1 2 3 4 ...

Page 9: ...ing gas in the refrigerating circuit Compressor is malfunction Voltage is too high or too low System circuit is blocked Outdoor unit and indoor unit heat exchanger is dirty The air filter is dirty Inlet outlet of indoor outdoor units is blocked Doors and windows are open Sunlight directly shine Too much heat resource Outdoor temp is too high Leakage of refrigerant or lack of refrigerant Wait for t...

Page 10: ...emote controller is properly directed to the infrared signal receiver of the indoor unit when the ON OFF button is pressed Directly transmit the signal transmitter of the remote controller to the infrared signal receiver of the indoor unit and then repeatly push the ON OFF button twice The indication on the display disappears after a lapse of time Check whether the timer operation has come to an e...

Page 11: ...QS01U 007AW 202000171405 20130618 The design and s pecifications ar e subject to change without pr ior no tice for product improv ement Consult with the s ales agency or manufacturer for details ...