3.    AIR CONDITIONER OPENRATIONS AND 

       PERFORMANCE 

Use the system in the following temperature for safe and 
effective  operation.  The  Max  operation  temperature  for 
the air conditioner (Cooling/Heating). 

If air conditioner is used outside the above conditions, it 
may cause the unit to function abnormally. 

NOTE 

Table 3-1 

Table 3-2(for inverter type air conditioner) 

 

 

Cooling operation 

Drying operation 

Heating operation 

(cooling only  type without) 

Mode

Temperature

Outdoor 
temperature 

                            (for models with low  

                            temperature cooling system) 

                            (for special tropical models) 

                            (for special tropical models) 

temperature 

18

°

C ~ 43

°

C / 64 

°

F~109

°

F        

18

°

C ~ 52

°

C / 64 

°

F~126

°

F          

-7

°

C ~ 43

°

C / 20 

°

F~109

°

F

         

-7

°

C ~ 24

°

C / 20 

°

F ~ 76

°

F          

18

°

C ~ 43

°

C / 64 

°

F~109

°

F         

18

°

C ~ 52

°

C / 64 

°

F~126

°

F         

0

°

C ~ 30

°

C / 32 

°

F~86

°

F

  17

°

C ~ 32

°

C

( 62 

°

F ~ 90

°

F)

  17

°

C ~ 32

°

C

( 62 

°

F ~ 90

°

F)

0

°

C ~ 30

°

C / 32 

°

F~86

°

F

  17

°

C ~ 32

°

C

( 62 

°

F ~ 90

°

F)

  17

°

C ~ 32

°

C

( 62 

°

F ~ 90

°

F)

 

 

Cooling operation 

Drying operation 

Heating operation 

(cooling only  type without) 

Mode

Temperature

Outdoor 
temperature 

                            (for models with low  

                            temperature cooling system) 

temperature 

0

°

C ~ 50

°

C / 32 

°

F~122

°

F          

0

°

C ~ 50

°

C / 32 

°

F~122

°

F      

-15

°

C ~ 50

°

C / 5 

°

F~122

°

         

-15

°

C ~ 24

°

C / 5 

°

F~76

°

F          

The  phenomenon  is  normal  that  the  surface  of  air 
conditioning  may  condense  water  when  the  relative 
larger  humidity  in  room,  please  close  the  door  and 
window.

Optimum  performance  will  be  achieved  within  these 
operating temperature range. 

4.    HINTS FOR ECONOMICAL OPERATION 

The  following  should  be  noticed  to  ensure  an  economical 
operation. 

Adjust  the  air  flow  louver  properly  and  avoid  direct  air  flow  to 
room inhabitants. 
 
Adjust  the  room  temperature  properly  for  a  comfortable 
environment. Avoid excessive heating or cooling. 
 
Prevent  direct  sunlight  during  cooling  operation  by  using 
curtains or blinds. 
 
Ventilate  often.  Extended  use  requires  special  attention  to 
ventilation. 
 
Keep  doors  and  windows  closed.  If  the  doors  and  windows 
remain open, air will flow out of your room causing a decrease 
in the cooling or heating effect. 
 
Never place objects near the air inlet or the air outlet of the unit. 
It may cause deterioration in the effect or stop the operation. 
 
Set the timer . 
 
If you don't plan to use the unit for a long time, please take the 
batteries  from  the  remote  controller.  When  the  power  is  on, 
some energy will be consumed,even if the air conditioner isn't in 
operation. So please disconnect the power to save energy.  

Keep  the  indoor  unit  and  remote  controller  at  least  1  m  away 
from  televisions,  radios,  stereos,  and  other  similar  equipment. 
Failing to do so may cause static or distorted pictures. 
 
A  dirty  air  filter  will  reduce  cooling  or  heating  efficiency, please 
clean it once two weeks. 

5.    ADJUSTING AIR FLOW DIRECTION 

While the unit is in operation, you can adjust the air flow louver 
to  change  the  flow  direction  and  naturalize  the  room 
temperature evenly. Thus you can enjoy it more comfortably.  
 

Set the air flow direction.

 

Press  the    SWING    button  to  adjust  the  louver  to  the  desired 
position  and  press  this  button  again  to  maintain  the  louver  at 
this position. 
 

Adjust the air flow direction automatically.

 

Press the SWING button, the louver will swing automatically. 
While  this  function  is  set,  the  swing  fan  of  indoor  unit  runs; 
otherwise,  the  swing fan  doesn't  run. The  swing scale  of every 
side is 30

°

. When the air conditioner isn't in operation (including 

when TIMER ON is set),  the SWING button will be invalid. 
 

Adjust it up and down 

      Fig 5-1 

 

 

Three-minute protection feature 

A  protection  feature  prevents  the  air  conditioner  from  being 
activated for approximately 3 minutes  
when it restarts immediately after operation. 

Power failure 

Power failure during operation will stop the unit completely. 

Disconnect the unit with the power and then connect the unit 
with the power again. Push the ON/OFF button on the remote 
controller to restart operation. 

        The OPERATION lamp on the indoor unit will start 
        flashing when power is restored. 
 
        To restart operation, push the ON/OFF button on the            
         remote controller. 
 
        Lightning or a car wireless telephone operating nearby  
        may cause the unit to malfunction. 

Summary of Contents for ICS0629C21

Page 1: ... Cassette Type OWNER S MANUAL Thank you very much for purchasing our air conditioner Before using your air conditioner please read this manual carefully and keep it for future reference ICS0629C21 ICS0736C21 ICS0848C21 ...

Page 2: ...te controller Air outlet Refrigerant pipe Air filter inside air in grill Air inlet Air inlet Air inlet Air outlet 3 9 10 10 11 11 11 11 11 11 12 12 12 All the pictures in this manual are for explanation purpose only They may be slightly different from the air conditioner you purchased depend on model The actual shape shall prevail NOTE OR 10 11 1 5 7 8 2 4 6 Fig 1 ...

Page 3: ...connection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundeater and get into the food chain damaging your health and well being To prevent refrigerant leak contact your dealer When the system is installed and runs in a small room it is required to keep the concentration of the refrigerant if by any chance coming out bel...

Page 4: ... without supervision This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance If the suppl...

Page 5: ...se in the cooling or heating effect Never place objects near the air inlet or the air outlet of the unit It may cause deterioration in the effect or stop the operation Set the timer If you don t plan to use the unit for a long time please take the batteries from the remote controller When the power is on some energy will be consumed even if the air conditioner isn t in operation So please disconne...

Page 6: ... the air filter shown in Fig 6 1 Pull the air in grill down at 45 and lift it up to take out the grill Dismantle the air filter Clean the air filter Vacuum cleaner or pure water may be used to clean the air filter If the dust accumulation is too heavy please use soft brush and mild detergent to clean it and dry out in cool place The air in side should face up when using vacuum cleaner See Fig 6 3 ...

Page 7: ...erly operate except the above mentioned cases or the above mentioned malfunctions is evident investigate the system according to the following procedures See in Table 8 3 8 1 Troubles and causes of air conditioner Symptom 5 Dust comes out of the unit Symptom 6 The units can give off odours When the unit is used for the first time in a long time This is because dust has gotten into the unit The uni...

Page 8: ...Quick flash E1 10 11 Indoor master slave unit communication checking channel is abnormal F3 Quick flash Quick flash Other malfunctions of master slave unit F4 Quick flash Quick flash Outdoor unit malfunction Ed Slow flash Collision model malfunction E0 Quick flash Table 8 2 Applicable to fixed frequency air conditioner only NO Malfunction running lamp timer lamp defrosting lamp alarm lamp 1 2 3 4 ...

Page 9: ...ing gas in the refrigerating circuit Compressor is malfunction Voltage is too high or too low System circuit is blocked Outdoor unit and indoor unit heat exchanger is dirty The air filter is dirty Inlet outlet of indoor outdoor units is blocked Doors and windows are open Sunlight directly shine Too much heat resource Outdoor temp is too high Leakage of refrigerant or lack of refrigerant Wait for t...

Page 10: ...emote controller is properly directed to the infrared signal receiver of the indoor unit when the ON OFF button is pressed Directly transmit the signal transmitter of the remote controller to the infrared signal receiver of the indoor unit and then repeatly push the ON OFF button twice The indication on the display disappears after a lapse of time Check whether the timer operation has come to an e...

Page 11: ...QS01U 007AW 202000171405 20130618 The design and s pecifications ar e subject to change without pr ior no tice for product improv ement Consult with the s ales agency or manufacturer for details ...

Reviews: