background image

owner

s manual 

 

Do not operate the air conditioner with a wet hand. 

 

An electric shock may happen.  
 

Do not touch the heat exchanger fins. 

 

These fins are sharp and could result in cutting injuries. 
 

Do  not  place  items  which  might  be  damaged  by  moisture 
under the indoor unit. 

 

Condensation  may  form  if  the  humidity  is  above  80%,  the  drain 
outlet is blocked or the filter is polluted.  
 

After a long use, check the unit stand and fitting for damage.

  

If damaged, the unit may fall and result in injury. 
 

To avoid oxygen deficiency, ventilate the room sufficiently if 
equipment  with  burner  is  used  together  with  the  air 
conditioner.

 

 

Arrange the drain hose to ensure smooth drainage.

 

Incomplete  drainage  may  cause  wetting  of  the  building,  furniture 
etc. 
 

Never touch the internal parts of the controller.

  

Do not remove the front panel. Some parts inside are dangerous 
to touch, and a machine trouble may happen. 
 

Never expose little children, plants or animals directly to  
the air flow. 

 

Adverse influence to little children, animals and plants may result. 

 
Do  not  allow  a  child  to  mount  on  the  outdoor  unit  or  avoid 
placing any object on it.

  

Falling or tumbling may result in injury. 

 
Do  not  operate  the  air  conditioner  when  using  a  room 
fumigation - type insecticide. 

 

Failure  to  observe  could  cause  the  chemicals  to  become 
deposited  in  the  unit,  which  could  endanger  the  health  of  those 
who are hypersensitive to chemicals. 

 
Do  not  place  appliances  which  produce  open  fire  in  places 
exposed to the air flow from the unit or under the indoor unit.

  

It  may  cause  incomplete  combustion  or  deformation  of  the  unit 
due to the heat. 
 

Do  not  install  the  air  conditioner  at  any  place  where 
flammable gas may leak out.  

If  the  gas  leaks  out  and  stays  around  the  air  conditioner,  a  fire 
may break out.  
 

This  appliance  can  be  used  by  children  aged  from  8  years 
and    above  and  persons  with  reduced  physical,  sensory  or 
mental    capabilities  or  lack  of  experience  and  knowledge  if 
they have  been given supervision or instruction concerning 
use  of  the  appliance  in  a  safe  way  and  understand  the 
hazards involved. Children shall not play with the appliance. 
Cleaning    and    user    maintenance  shall  not  be  made  by 
children without supervision. 
 
This appliance is not intended for use by persons (including  
children)  with  reduced  physical,  sensory    or    mental  
capabilities,  or  lack  of  experience  and  knowledge,  unless 
they  have been given supervision or instruction concerning 
use  of    the  appliance  by  a  person  responsible  for  their 
safety. 
 
Children  should  be  supervised  to  ensure  that  they  do  not 
play with the appliance. 
 
If  the  supply  cord  is  damaged,  it  must  be  replaced  by  the 
manufacturer, its service agent or similarly qualified persons 
in order to avoid a hazard. 
 
Do not operate your air conditioner in a wet room such as a 
bathroom or laundry room. 
 

Display panel

             

Fig.2-2 

PRE-DEF indicator(cooling and heating type)  
or fan only indicator(cooling only type) 

Infrared signal receiver 

Operation lamp 

Timer indicator 

Alarm indicator 

Temporary button 

This  manual  does  not  include  Remote  Controller 
Operations,  see  the<<Remote  Controller  Owner's 
manual>> packed with the unit for details.  

NOTE 

2.    PARTS  NAMES 

The air conditioner consists of the indoor unit, the outdoor unit, 
the connecting pipe and the remote controller. 

(See Fig.2    ) 

Function indicators on indoor unit display panel 

FORCED AUTO

 

The  OPERATION  lamp  is  lit,  and  the  air  conditioner  will  run 
under FORCED AUTO mode. The remote controller operation is 
enabled to operate according to the received signal. 

 

FORCED

 

COOL

 

The  OPERATION  lamp  flashes,  the  air  conditioner  will  turn  to 
FORCED AUTO after it is enforced to cool with a wind speed of 
HIGH  for  30  minutes.  The  remote  controller  operation  is 
disabled. 
  
OFF

 

The  OPERATION  lamp  goes  off.  The  air  conditioner  is  OFF 
while the remote controller operation is enabled.

 

For  inverter  type,this  switch  is  used  for  after-sales  service 
purpose only,the user should not push it. 

For fixed-frequency type,

this function is used to operate the unit 

temporarily in case you misplace  the  remote  controller  or  its 
batteries  are  exhausted. Two  modes  including 

FORCED 

AUTO  and  FORCED  COOL  can  be selected  through  the 
TEMPORARY  BUTTON  on  the  air-in  grill control box of the 
indoor unit. Once you push this button, the air conditioner  will 
run  in  such  order: 

FORCED 

AUTO,  FORCED  COOL, OFF, 

and back to 

FORCED 

AUTO.    

 

Display panel

             

Fig.2-1 

PRE-DEF indicator(cooling and heating type)  
or fan only indicator(cooling only type) 

Infrared signal receiver 

Operation lamp 

Timer indicator 

Alarm indicator 

Temporary button 

Summary of Contents for ICS0629C21

Page 1: ... Cassette Type OWNER S MANUAL Thank you very much for purchasing our air conditioner Before using your air conditioner please read this manual carefully and keep it for future reference ICS0629C21 ICS0736C21 ICS0848C21 ...

Page 2: ...te controller Air outlet Refrigerant pipe Air filter inside air in grill Air inlet Air inlet Air inlet Air outlet 3 9 10 10 11 11 11 11 11 11 12 12 12 All the pictures in this manual are for explanation purpose only They may be slightly different from the air conditioner you purchased depend on model The actual shape shall prevail NOTE OR 10 11 1 5 7 8 2 4 6 Fig 1 ...

Page 3: ...connection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundeater and get into the food chain damaging your health and well being To prevent refrigerant leak contact your dealer When the system is installed and runs in a small room it is required to keep the concentration of the refrigerant if by any chance coming out bel...

Page 4: ... without supervision This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance If the suppl...

Page 5: ...se in the cooling or heating effect Never place objects near the air inlet or the air outlet of the unit It may cause deterioration in the effect or stop the operation Set the timer If you don t plan to use the unit for a long time please take the batteries from the remote controller When the power is on some energy will be consumed even if the air conditioner isn t in operation So please disconne...

Page 6: ... the air filter shown in Fig 6 1 Pull the air in grill down at 45 and lift it up to take out the grill Dismantle the air filter Clean the air filter Vacuum cleaner or pure water may be used to clean the air filter If the dust accumulation is too heavy please use soft brush and mild detergent to clean it and dry out in cool place The air in side should face up when using vacuum cleaner See Fig 6 3 ...

Page 7: ...erly operate except the above mentioned cases or the above mentioned malfunctions is evident investigate the system according to the following procedures See in Table 8 3 8 1 Troubles and causes of air conditioner Symptom 5 Dust comes out of the unit Symptom 6 The units can give off odours When the unit is used for the first time in a long time This is because dust has gotten into the unit The uni...

Page 8: ...Quick flash E1 10 11 Indoor master slave unit communication checking channel is abnormal F3 Quick flash Quick flash Other malfunctions of master slave unit F4 Quick flash Quick flash Outdoor unit malfunction Ed Slow flash Collision model malfunction E0 Quick flash Table 8 2 Applicable to fixed frequency air conditioner only NO Malfunction running lamp timer lamp defrosting lamp alarm lamp 1 2 3 4 ...

Page 9: ...ing gas in the refrigerating circuit Compressor is malfunction Voltage is too high or too low System circuit is blocked Outdoor unit and indoor unit heat exchanger is dirty The air filter is dirty Inlet outlet of indoor outdoor units is blocked Doors and windows are open Sunlight directly shine Too much heat resource Outdoor temp is too high Leakage of refrigerant or lack of refrigerant Wait for t...

Page 10: ...emote controller is properly directed to the infrared signal receiver of the indoor unit when the ON OFF button is pressed Directly transmit the signal transmitter of the remote controller to the infrared signal receiver of the indoor unit and then repeatly push the ON OFF button twice The indication on the display disappears after a lapse of time Check whether the timer operation has come to an e...

Page 11: ...QS01U 007AW 202000171405 20130618 The design and s pecifications ar e subject to change without pr ior no tice for product improv ement Consult with the s ales agency or manufacturer for details ...