2. Timer: When adjust setting on time or only on time is set, the “ON” is lighted. When adjust setting off
time or only off time is set, the” OFF" is lighted. If on and off timer are both set, the “ON” and “OFF” are
both lighted.
3. Follow me function: There is a temperature sensor inside the wire controller, after setting temperature, it
will compare the two temperatures, and the space of wire controller will be the same as setting
temperature. It is available under cooling, heating, auto mode.
4 ON/OFF indication: When it is on, the icon display, otherwise it is extinguished.
5. Fan speed indication: There are four fan modes: low, middle, high, auto. For some models, no middle
fan then the middle fan is seen as high speed.
6. Lock: When the "LOCK" button is pressed, the icon appears and other buttons is unable, press again,
the icon disappears.
7. Temperature display zone: Generally it displays setting temperature; it can be adjusted by press
temperature button
▲
and
▼
.But in fan mode, no display here.
Remark:
The wired controller will reset to factory setting with auto mode, auto fan and 24
℃
setting temperature when
the air conditioner restarts after power failure.
And this may cause inconsistent displays on the wired controller and on the air conditioner. You need to
readjust the running status through the wired controller.
Installation
Installation Notice:
When the air conditioner needs the constant frequency wire controller, be sure adding a wire joint with 5
terminal named A, B, C, D, E in indoor unit, and fixing an infrared emitter whose anode and cathode
connecting with A and B near the receiver in the indoor unit switch board, then connecting the te5v,
GND, Run in the switch board to C,D,E respectively.
98
Electrical Control System
Summary of Contents for ICS0629C21
Page 1: ...SERVICE MANUAL IOS629C2V01 IOS736C2V01 IUS0736C21 ICS0629C21 ICS0736C21 AIR CONDITIONER i ...
Page 2: ......
Page 4: ......
Page 9: ...Part 2 Indoor Units Four way Cassette Type 6 Ceiling Floor Type 20 5 ...
Page 13: ......
Page 16: ...Service Space 3 Service Space 1000mm 1000mm 1000mm 1000mm 12 Four way Cassette Type ...
Page 17: ...Wiring Diagrams 4 Wiring Diagrams ICS0629C21 ICS0736C21 Four way Cassette Type 13 ...
Page 23: ...Field Wiring 11 Field Wiring ICS0629C21 ICS0736C21 Four way Cassette Type 19 ...
Page 27: ...Service Space 3 Service Space Ceiling Floor Type 23 ...
Page 28: ...Wiring Diagrams 4 Wiring Diagrams IUS0736C21 24 Ceiling Floor Type ...
Page 35: ...Field Wiring 11 Field Wiring IUS0736C21 Ceiling Floor Type 31 ...
Page 40: ...Wiring Diagrams 3 Wiring Diagrams IOS629C2V01 36 Outdoor Unit ...
Page 41: ...Wiring Diagrams IOS736C2V01 Outdoor Units 37 ...