18
CONDENSATE DRAIN OPTIONS
HPAC 2.0 is equipped with a pump and spray head which sprays the collected condensate on to the heat exchanger
coil in cooling mode. This evaporates the condensate, eliminating the need for a condensate drain. In heating mode, or if
used to cool in low ambient temperatures (below 73.5°F) this procedure is not feasible and therefore a condensate drain is
required.
Determine where the condensate drain will be located:
IN-WALL DRAIN
This is the best type of drain where it is installed by a plumber inside the wall
DIRECT EXTERIOR DRAIN
This is the easiest type of drain where the condensate drips straight outside.
NEBULIZER:
Innova offers an optional nebulizer kit, which atomizes the condensate in heat mode as a fine mist through an additional
exterior hole.
Follow appropriate instructions on the following pages depending on your particular type of installation.
Note:
The unit does not drain the condensate directly into the drain pipe, but rather it collects into a lightly heated
collection pan (to eliminate icing up of the liquid) where a solenoid valve controls the flow of the condensate from the
internal collection tray to the drain pipe once the maximum level has been reached.