16
STEP 1
Attach the mounting template to the wall with tape
STEP 2
Drill the holes for the XVentBox in accordance with the specifications of the grille style you are
using.
STEP 3
Afix the wall mount bracket as indicated on the Template. The bracket must be affixed to studs
or other suitable material that can safely support the weight of the unit. Do not use hollow wall
anchors.
STEP 4
If using an external drain for condensate, drill a hole as indicated on the template for the
condensate to drain outside. Make sure to drill the hole at a 3 degree downward angle.
STEP 5
If the anti-lifting bracket hole does not line up with a stud, install a hollow wall anchor.
STEP 6
If hardwiring the unit make sure the junction box and appropriate connections are located in
the electrical connection area.
A
Holes for fastening wall bracket
B
Electrical connection area
C
Holes for air vent pipes
D
Holes for external condensate drain
E
Anti-lifting bracket hole
PREPARATION
Once the location for the unit has been determined following all the requirements follow these steps: