![Innolas Laser nanio Series User And Installation Manual Download Page 17](http://html1.mh-extra.com/html/innolas-laser/nanio-series/nanio-series_user-and-installation-manual_2062634017.webp)
2.4.2. Water/water
Figure 10 - Water/water chiller
Water/water chillers are available in standard and clean-room versions. They are
designed for high average power or high duty cycle applications. Both versions fit into
a 19–inch rack and are 4RU high. External water pipe connections are xx flow and xx
return.
Water/water chillers require an external water supply with minimum flow rate of
8 l/min and pressure differential of 100 kPa
2.5. Beam Delivery Options
• Beam expander
• Scan head mounting option
2.6. Specifications
2.6.1. Electrical supply
Maximum power consumption
1.5 kVA
Maximum current demand
16 A
Supply voltage
Single phase 115–230 VAC ± 10%
Supply frequency
50/60 Hz
nanio Industrial DPSS Laser User and Installation Manual
9
2. General Description
Summary of Contents for nanio Series
Page 6: ......
Page 8: ...InnoLas Laser GmbH Preface ii...
Page 14: ...InnoLas Laser GmbH 1 Safety 6...
Page 18: ...2 6 2 Dimensions Figure 11 490 mm head InnoLas Laser GmbH 2 General Description 10...
Page 22: ...InnoLas Laser GmbH 2 General Description 14...
Page 28: ...InnoLas Laser GmbH 4 Software 20...
Page 34: ...InnoLas Laser GmbH 6 Troubleshooting 26...
Page 40: ...InnoLas Laser GmbH 7 Installation 32...
Page 48: ...InnoLas Laser GmbH 40...